MétaCan
Menu
Back to cohort
Record W4377220459 · doi:10.1093/eurheartjsupp/suad101

ANMCO position paper: guide to the appropriate use of the wearable cardioverter defibrillator in clinical practice for patients at high transient risk of sudden cardiac death

2023· article· en· W4377220459 on OpenAlexaff
Giancarlo Casolo, Michele Massimo Gulizia, Daniela Aschieri, Alessandra Chinaglia, Marco Corda, Daniele Nassiacos, Salvatore Ivan Caico, Cristina Chimenti, Marzia Giaccardi, Enrico Gotti, Stefano Maffè, R Magnano, G. Solarino, Domenico Gabrielli, Fabrizio Oliva, Furio Colivicchi

Bibliographic record

VenueEuropean Heart Journal Supplements · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsHealth Care Foundation
Fundersnot available
KeywordsMedicineGuidelineSudden cardiac deathVentricular fibrillationIntensive care medicineCardiologyRisk stratificationInternal medicineVentricular tachycardiaRisk assessment

Abstract

fetched live from OpenAlex

Extended risk stratification and optimal management of patients with a permanently increased risk of sudden cardiac death (SCD) are becoming increasingly important. There are several clinical conditions where the risk of arrhythmic death is present albeit only transient. As an example, patients with depressed left ventricular function have a high risk of SCD that may be only transient if there will be a significant recovery of function. It is important to protect the patients while receiving and titrating to the optimal dose the recommended drugs that may lead to an improved left ventricular function. In several other conditions, a transient risk of SCD can be observed even if the left ventricular function is not compromised. Examples are patients with acute myocarditis, during the diagnostic work-up of some arrhythmic conditions or after extraction of infected catheters while eradicating the associated infection. In all these conditions, it is important to offer a protection to these patients. The wearable cardioverter defibrillator (WCD) is of particular importance as a temporary non-invasive technology for both arrhythmia monitoring and therapy in patients with increased risk of SCD. Previous studies have shown the WCD to be an effective and safe therapy for the prevention of SCD caused by ventricular tachycardia/fibrillation. The aim of this ANMCO position paper is to provide a recommendation for clinical utilization of the WCD in Italy, based upon current data and international guidelines. In this document, we will review the WCD functionality, indications, clinical evidence, and guideline recommendations. Finally, a recommendation for the utilization of the WCD in routine clinical practice will be presented, in order to provide physicians with a practical guidance for SCD risk stratification in patients who may benefit from this device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.029
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Other · Consensus signal: Other
Teacher disagreement score0.091
Threshold uncertainty score0.303

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.029
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0020.002
Science and technology studies0.0010.001
Scholarly communication0.0040.004
Open science0.0020.002
Research integrity0.0090.006
Insufficient payload (model declined to judge)0.0910.138

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.353
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart Journal SupplementsSame topicCardiac pacing and defibrillation studiesFrench-language works237,207