MétaCan
Menu
← Back to cohort

Active aluminum window-frame integrated prototype with a thermoelectric heat recovery system for ventilation and air conditioning

2022· article· en· W4377250188 on OpenAlexaff
Pablo Arias-Salazar, Marina Vidaurre-Arbizu, José Antonio Sacristán-Fernández, César Martín-Gómez, José Ramón Couso-San Martín, Jorge Fernández-Heras, Amaia Zuazua-Ros

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsBC Hydro (Canada)
FundersGobierno de NavarraUniversidad de Navarra
KeywordsThermoelectric coolingAir conditioningThermoelectric effectBuilding envelopeSolar gainMechanical engineeringPassive coolingActive coolingThermoelectric generatorNatural ventilationEngineeringWater coolingHeat transferComputer scienceEnvironmental scienceVentilation (architecture)Electrical engineeringMeteorologyThermalMechanicsSolar energyThermodynamicsPhysics

Abstract

fetched live from OpenAlex

Research interest in the integration of thermoelectric systems in the building envelope have increased during the last years. Studies show that regardless of a low COP compared to vapor compression systems; thermoelectric systems present other remarkable features for heating, cooling and ventilation on buildings. Among those studies, a few prototype experiences incorporate thermoelectric systems on windows.Alternatively, standard air conditioning systems often require additional equipment installed on façade or wall surfaces that compromise the use of space in the case of building refurbishment. Thus, the integration of thermoelectric systems on window framing is presented here as a decentralized alternative for air conditioning support, whose performance aims at balancing out the heat losses in windows. The purpose of this communication is to present the development of an active aluminum window-framing prototype with a thermoelectric heat recovery system for heating and cooling. In a typical single-floor house scenario, the active window-frame works in two different modes: pre heating/cooling mode applying forced convection through a mechanical fan and pre heating/cooling mode with natural convection. The impulsion airflow rate meets ventilation requirements according to Spanish Technical Building Code (CTE) for indoor air quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.172
Teacher spread0.168 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same topicBuilding Energy and Comfort Optimization→French-language works237,207→