MétaCan
Menu
Back to cohort
Record W4378234208 · doi:10.1093/europace/euad122.441

Long term conservation of electrical synchrony by multipoint pacing with dynamic atrioventricular delays

2023· article· en· W4378234208 on OpenAlexaff
Bernard Thibault, Anthony Chow, Jan O. Mangual, Nima Badie, P Waddingham, L. Mcspadden, Timothy R. Betts, Leonardo Calò, Francisco Leyva

Bibliographic record

VenueEP Europace · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMontreal Heart Institute
Fundersnot available
KeywordsMedicineQRS complexImplantVentricleCardiac resynchronization therapyCardiologyEjection fractionInternal medicineSurgeryHeart failure

Abstract

fetched live from OpenAlex

Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Abbott. Introduction Automatic adjustment of atrioventricular delay (AVD) with SyncAV has been shown to improve electrical synchronization. However, the long term effects of SyncAV optimization on electrical synchrony are unknown. Purpose Evaluate the effect of SyncAV programming on 6-month (6mo) QRS duration during biventricular (BiV) and left ventricle only MultiPoint Pacing (MPP). Methods Patients with LBBB and QRS duration (QRSd) ≥ 150 ms scheduled for CRT-P/D device implantation with quadripolar LV lead were enrolled in this prospective study. QRSd was measured post-implant from 12-lead surface ECG by blinded experts during the following pacing modes: intrinsic conduction, MPP (MPP=RV+LV1+LV2) and LV-only MPP (LVMPP=LV1+LV2). For each mode, SyncAV was enabled (e.g. MPP+SyncAV) with the patient-tailored SyncAV offset that minimized QRSd. Patients were then randomized 1:1 to receive MPP+SyncAV or LVMPP+SyncAV with the optimal offset identified at implant, and QRSd was re-evaluated at the 6mo follow-up. Results Fifty-nine patients (72% male, 41% ischemic, 26% ejection fraction, 166 ms intrinsic QRSd) completed device implant and QRSd assessment. Relative to intrinsic conduction at implant, the MPP+SyncAV group (n=30) had a QRSd reduction of 26% at implant (162 to 122 ms, p<0.001), and 20% at 6mo (162 to 130 ms, p<0.001). The LVMPP+SyncAV group (n=29) had a QRSd reduction of 24% at implant (165 to 128 ms, p<0.001), and 15% at 6mo (165 to 140 ms, p<0.001). In the MPP+SyncAV group, 28/30 (93%) of patients had more than 10% reduction in QRSd with respect to intrinsic at implant, with 27/30 (90%) maintaining this trend at 6 mo follow up. With LVMPP+SyncAV pacing, only 25/29 (86%) of patients had more than 10% reduction in QRSd with respect to intrinsic at implant, and this reduced to 18/29 (62%) maintaining this trend at 6 mo follow up. Conclusion MPP combined with SyncAV significantly improved acute electrical synchrony at implant in CRT patients with LBBB, as assessed by QRSd reduction. Significant QRSd reduction was maintained at 6 months post-implant by both biventricular and LV-only MPP configurations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.039
Threshold uncertainty score0.399

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.262
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueEP EuropaceSame topicCardiac pacing and defibrillation studiesFrench-language works237,207