Comparison of the Mechanical and Osseointegrative Performance of Porous Tantalum and Titanium for Acetabular Implantation in Total Hip Arthroplasty: A Literature Review

2023· review· en· W4380624997 on OpenAlexaff
Margaret S. Juryn

Bibliographic record

VenueUndergraduate Research in Natural and Clinical Science and Technology (URNCST) Journal · 2023
Typereview
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsOsseointegrationImplantContext (archaeology)TitaniumMaterials scienceTotal hip arthroplastyBiomedical engineeringSurgeryMedicine

Abstract

fetched live from OpenAlex

Introduction: Stability of the acetabular component is a critical factor in the success of primary and revision total hip arthroplasty (THA) procedures. As such, the identification of implant surface characteristics that maximize stability of the acetabular cup is an important research objective. While titanium has historically been the most commonly used implant material, the proportion of THA procedures utilizing porous tantalum (PTa) implants has increased in recent years. The objective of this review is to examine the comparative mechanical and osseointegrative performance of PTa and porous titanium (PTi) and interpret these results in the context of primary and secondary stability of acetabular implants in THA, as characterized by strength of initial mechanical attachment and successful interlocking at the bone-implant interface, respectively. Methods: A literature search using a predetermined protocol and inclusion criteria yielded 7 articles presenting results of comparative testing of mechanical performance or osseointegration of PTa and PTi in the context of THA. Results: Neither PTa nor PTi presented consistently superior results in mechanical tests designed to correlate to primary stability at the metallo-biological surface nor in measures of osseointegration intended to represent secondary stability in THA. Discussion: In comparing PTa and PTi, it appears that the characteristics of the implant coating's pores may have a more significant impact on factors affecting the stability of an acetabular cup implant than the metal selected. However, determining the ideal pore morphology for this application is complex; pore characteristics that would suggest mechanical compatibility may conflict with those that would encourage more effective osseointegration. Conclusion: When extrapolated to be indicators of hypothetical clinical success, the results of this review are consistent with those of recently released macro-analyses of clinical outcomes: PTa and PTi acetabular cups, as they are currently manufactured, produce clinically equivalent outcomes. In the development and comparison of coating options, pore morphology and its complex effects on stability must be adequately accounted for; only then can we reach a faithful conclusion regarding the ideal porous adhesion surface for acetabular implant in THA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.013
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.002
Bibliometrics0.0130.016
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.100
GPT teacher head0.470
Teacher spread0.370 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueUndergraduate Research in Natural and Clinical Science and Technology (URNCST) JournalSame topicOrthopaedic implants and arthroplastyFrench-language works237,207