MétaCan
Menu
Back to cohort
Record W4381851488 · doi:10.1016/j.ejmp.2023.102623

Advanced automated treatment planning for total body irradiation: Implementation and effects on standardization

2023· article· en· W4381851488 on OpenAlexaff
Rebecca Frederick, Lukas Van Dyke, Alana Hudson, Greg Pierce

Bibliographic record

VenuePhysica Medica · 2023
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsFoothills Medical CentreUniversity of Calgary
Fundersnot available
KeywordsStandard deviationStandardizationMedicineAutomationNuclear medicineStatisticsComputer scienceSimulationMathematicsMedical physicsEngineeringOperating system

Abstract

fetched live from OpenAlex

PURPOSE: This work describes the automation of our volumetric modulated arc therapy (VMAT) total body irradiation (TBI) treatment planning. It also aims to determine if plan standardization is impacted by automation. METHODS: We introduced automated beam placement for TBI in March 2021. For manual beam placement pre-2021, Python-modified DICOM files were imported to pre-set cumulative meterset weights, with other parameters selected by dosimetrists. Our automated planning script automates these processes and sets gantry stop angles and isocentre placement. To determine the impact of automation on plan standardization, we performed a retrospective review of a matched cohort of 168 patients. Plan parameters were compared with an external standard, and passing rates compared between patient cohorts. The dosimetric impact was investigated by comparing a Body-5 mm homogeneity index (HI = D2%/D98%) and mean lung dose (MLD) between cohorts. RESULTS: Results are listed for manual and automated groups respectively. Median (range) passing rates were 97.7% (96.1-100) and 99.2% (98.3-100). Automated plans had a significantly higher passing rate (p ≪ 0.05) and smaller variance (p = 0.001). Most failures were attributed to human error. Automated plans also had more consistent parameter identifiers. After considering dimensional outliers, median (range) Body-5 mm HI were 1.18 (1.14-1.23) and 1.18 (1.15-1.26), and mean ± standard deviation MLD were 103.8 ± 1.3% and 104.1 ± 0.9%. Variances were not significantly different between Body-5 mm HI (p = 0.092) but were for MLD (p = 0.013). CONCLUSIONS: Implementation of automated planning in TBI resulted in significantly improved plan standardization. The decrease in variance of the MLD for the automated planning group points towards a potential dosimetric benefit of automation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.024
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.044

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.024
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.357
Teacher spread0.348 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2023
Admission routes1
Has abstractyes

Explore more

Same venuePhysica MedicaSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207