MétaCan
Menu
← Back to cohort
Record W4382199292 · doi:10.1088/1361-6560/ace23f

Static couch non-coplanar arc selection optimization for lung SBRT treatment planning

2023· article· en· W4382199292 on OpenAlexafffund
John Lincoln, R Lee MacDonald, Alasdair Syme, Christopher G. Thomas

Bibliographic record

VenuePhysics in Medicine and Biology · 2023
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsHealth Sciences CentreNova Scotia Health AuthorityDalhousie University
FundersCanadian Institutes of Health Research
KeywordsContext (archaeology)Arc (geometry)Nuclear medicineMedicineComputer scienceMathematicsAlgorithmGeometry

Abstract

fetched live from OpenAlex

Abstract Objective . Non-coplanar arc geometry optimizations that take advantage of beam’s eye view (BEV) geometric overlap information have been proven to reduce dose to healthy organs-at-risk (OARs). Recently, a metric called mean arc distance (MAD) has been developed that quantifies the arc geometry sampling of 4 π space. The purpose of this research is to combine improved BEV overlap information with MAD to generate static couch lung stereotactic body radiotherapy (SBRT) treatment plans deliverable on a C-arm linear accelerator. Approach . An algorithm utilizing the Moller–Trumbore ray-triangle intersection method was employed to compute a cost surrogate for dose to overlapping OARs using distances interpolated onto a PDD. Cost was combined with MAD for 100 000 random combinations of arc trajectories. A pathfinding algorithm for arc selection was created, balancing the contributions of MAD and 4 π cost for the final trajectory. This methodology was evaluated for 18 lung SBRT patients. Cases were also planned with arcs from a clinical treatment template protocol for dosimetric and plan quality comparison. Results were evaluated using dose constraints in the context of RTOG0915. Main results . Five of six OARs had maximum dose reductions when planned with the arc trajectory optimization algorithm. Significant maximum dose reductions were found for esophagus (7.41 ± 0.91 Gy, p = 0.00019), trachea (5.56 ± 1.55 Gy, p = 0.0025), spinal cord (2.87 ± 1.13 Gy, p = 0.039), large bronchus (3.47 ± 1.49 Gy, p = 0.0075), and aorta (3.13 ± 0.99 Gy, p = 0.012). Mean dose to contralateral lung was also significantly reduced (0.50 ± 0.06 Gy, p = 0.00019). There were two significant increases in OAR doses: mean dose to ipsilateral lung (0.40 ± 0.09, p = 0.00086) and V5 Gy to ipsilateral lung (1.95 ± 0.70%, p = 0.011). Paddick conformity index increased by 0.03 ± 0.02 ( p = 0.14), remaining below a limit of 1.2 for both techniques. Significance . Static couch non-coplanar optimization yielded maximum dose reductions to OARs while maintaining target conformity for lung SBRT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.007
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.428
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and Biology→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→