ADVANTAGES AND DISADVANTAGES OF HEART VALVE PROSTHESES WITH FLEXIBLE SUPPORTING FRAME COMPARED WITH THE CLASSIC STENTED PROSTHESES: EVALUATION OF THE HYDRODYNAMIC INDICATORS OF THE “UNILINE” AND “TIARA” BIOPROSTHESES

2023· article· en· W4382278446 on OpenAlexaboutno aff
K. Yu. Klyshnikov, Е. А. Овчаренко, Л. С. Барбараш

Bibliographic record

VenueComplex Issues of Cardiovascular Diseases · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsRegurgitation (circulation)Pulsatile flowBody orificeCardiologyInternal medicineMedicineHeart valveProsthesisAortic valveHemodynamicsBiomedical engineeringMaterials scienceSurgeryAnatomy

Abstract

fetched live from OpenAlex

Highlights The «TiAra» bioprosthetic heart valves have better hemodynamic characteristics, such as higher effective orifice area and a lower mean pressure gradient. The «UniLine» bioprosthetic heart valve demonstrated better closing dynamic, expressed in a smaller regurgitation volume. Aim. To assess hydrodynamic characteristics of the «TiAra» bioprosthetic heart valve with flexible supporting frame compared with the classic stented «UniLine» bioprosthetic aortic valve. Methods. Using the Vivitro Pulse Duplicator (Vivitro Labs, Canada), we simulated the function of the heart via generating pulsatile flow to analyze bioprosthetic heart valves. To comprehensively assess the bioprosthesis function, three valves of each standard size (21, 23, 25 mm) were submitted to hydrodynamic testing, thus making a sample of nine bioprostheses of each model. The article provides the analysis of the effective orifice area, mean pressure gradient, regurgitation volume, and assessment of the statistical sensitivity of the parameters between groups at p = 0.05. Results. The assessment revealed that the «TiAra» bioprosthesis has bigger effective orifice area (p = 0.006) and lower mean pressure gradient (p = 0.02): 1.6–2.2 cm 2 and 3.6–6.3 mmHg versus 1.08–1.73 cm 2 and 4.8–12.1 mmHg, respectively. The regurgitation volume, however, was lower in the «UniLine» bioprostheses 0.8–4.1 mL/cycle versus 6.2–9.0 mL/cycle (p = 0.0004). Conclusion. Despite the fact that both studied models showed good hydrodynamic performance, the prosthesis with the flexible supporting frame («TiAra») showed better results regarding its effectiveness in vitro via presenting with bigger effective orifice area and lower mean pressure gradient. At the same time, the «UniLine» stented bioprosthesis had lower regurgitation volume, i.e. better closing dynamics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.026
Threshold uncertainty score0.578

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.334
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueComplex Issues of Cardiovascular DiseasesSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207