MétaCan
Menu
← Back to cohort
Record W4383558759 · doi:10.1016/j.cjca.2023.07.005

Disparities in Referral and Utilization of Implantable Cardioverter-Defibrillators for Primary Prevention of Sudden Cardiac Death

2023· article· en· W4383558759 on OpenAlexaffvenueabout
Suzanne Boursalie, Ciorsti MacIntyre, John L. Sapp, Chris Gray, Amir AbdelWahab, Martin J. Gardner, David Lee, Kara Matheson, Ratika Parkash

Bibliographic record

VenueCanadian Journal of Cardiology · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsNova Scotia Health AuthorityDalhousie University
Fundersnot available
KeywordsMedicineEjection fractionPopulationOdds ratioConfidence intervalImplantable cardioverter-defibrillatorInternal medicineSudden cardiac deathReferralCardiologyPediatricsHeart failureFamily medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) reduce mortality in patients with reduced left ventricular ejection fraction (LVEF). We investigated sex disparities in a contemporary Canadian population for utilization of primary prevention ICDs. METHODS: This was a retrospective cohort study on patients with reduced LVEF admitted to hospitals from 2010 to 2020 in Nova Scotia (population = 971,935). RESULTS: There were 4406 patients eligible for ICDs: 3108 (71%) men and 1298 (29%) women. The mean follow-up time was 3.9 ± 3.0 years. Rates of coronary disease were similar between men and women (45.8% vs 44.0%; P = 0.28), but men had lower LVEF (26.6 ± 5.9% vs 27.2 ± 5.8%; P = 0.0017). The referral rate for ICD was 11% (n = 487), with 13% of men (n = 403) and 6.5% of women (n = 84) referred (P < 0.001). The ICD implantation rate in the population was 8% (n = 358), with 9.5% of men (n = 296) and 4.8% of women (n = 62) (P < 0.001) receiving the device. Men were more likely than women to receive an ICD (odds ratio 2.08, 95% confidence interval 1.61-2.70; P < 0.0001)). There was no significant difference in mortality between men and women (P = 0.2764). There was no significant difference in device therapies between men and women (43.8% vs 31.1%; P = 0.0685). CONCLUSIONS: A significant disparity exists in the utilization of primary prevention ICDs between men and women in a contemporary Canadian population.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.767
Threshold uncertainty score0.468

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.315
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of Cardiology→Same topicCardiac pacing and defibrillation studies→French-language works237,207→