MétaCan
Menu
Back to cohort
Record W4384342418 · doi:10.1177/15266028231187200

Technical Feasibility and Safety of a Snare-Less, EVAR–First Technique for Iliac Branch Endoprosthesis

2023· article· en· W4384342418 on OpenAlexaff
Julia Fayanne Chen, Sarah Loh, Uwe Fischer, Naiem Nassiri

Bibliographic record

VenueJournal of Endovascular Therapy · 2023
Typearticle
Languageen
FieldMedicine
TopicAortic aneurysm repair treatments
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsMedicineFluoroscopySurgeryCommon iliac arteryAortic bifurcationInternal iliac arteryEndovascular aneurysm repairExternal iliac arteryRadiologyFemoral arteryStentIliac arteryAneurysmAbdominal aortic aneurysmAorta

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose of this study was to evaluate the technical feasibility, safety, and early outcomes of a snare-less, endovascular abdominal aortic aneurysm repair (EVAR)-first technique (SET) for iliac branch endoprosthesis (IBE) placement. METHODS: We retrospectively reviewed all patients who received IBEs between July 2018 and March 2022. Patients were divided into 2 categories based on method of IBE deployment: SET or Standard. Primary endpoints were technical success, major adverse events, mortality, reintervention, internal iliac artery (IIA) patency, and freedom from IIA branch instability. Technical success was defined by successful deployment of both the EVAR and the IBE with maintained patency of the IIA and no stent graft migration. RESULTS: There were 20 patients (90% male, median age 72 [65.4-74.5] years) who underwent IBE placement. Among these, 5 (33.3%) underwent SET to treat 5 common iliac artery (CIA)/IIA aneurysms, while the remaining 15 (66.7%) underwent standard IBE deployment with through-and-through femoral access (n=13) or trans-brachial access (n=2) to treat 19 CIA/IIA aneurysms. Overall median renal to iliac bifurcation length was 169 (152-177) mm, with 9 patients falling short of the minimum of 165 mm for on-label IBE placement. Median contrast used was 148 (120-201) mL, fluoroscopy time 42.8 (35.0-49.8) minutes, estimated blood loss 200 (100-275) mL, and procedure time 192 (167-246) minutes, with no significant differences between the 2 groups. Technical success was achieved in 100% of cases. At 30 days, there were no mortalities or major adverse events in either group; there were 100% IIA patency, no IIA instability, and no reinterventions in both groups. Median follow-up in the SET group was 5.7 (5.5-6.2) months, with 1 death at 6 months and 1 type 1B endoleak at 6 months requiring reintervention. Median follow-up for the Standard group was 1.6 (0.8-2.1) years with 2 non-aneurysm-related deaths and no reinterventions at 1 year. CONCLUSIONS: SET for IBE is a safe and effective approach that decreases technical complexity and mitigates anatomic barriers to IBE placement. CLINICAL IMPACT: SET for IBE is a safe and effective approach to IBE placement that decreases technical complexity. A critical component to this technique is a large bore sheath with a stiff steerable tip. Importantly, this approach also mitigates anatomic barriers to IBE placement, expanding applicability of IBE technology to patients who may be otherwise ineligible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.248
Threshold uncertainty score0.616

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.308
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Endovascular TherapySame topicAortic aneurysm repair treatmentsFrench-language works237,207