MétaCan
Menu
← Back to cohort
Record W4384819818 · doi:10.1002/mp.16603

Technical note: System uncertainty on four‐ and eight‐channel parallel RF transmission for safe MRI of deep brain stimulation devices

2023· article· en· W4384819818 on OpenAlexaff
Benson P. Yang, Chih‐Hung Chen, Simon J. Graham

Bibliographic record

VenueMedical Physics · 2023
Typearticle
Languageen
FieldMedicine
TopicNeurological disorders and treatments
Canadian institutionsUniversity of TorontoMcMaster UniversitySunnybrook HospitalSunnybrook Health Science Centre
Fundersnot available
KeywordsRobustness (evolution)Computer scienceRadio frequencyDeep brain stimulationMagnetic resonance imagingElectromagnetic interferenceChannel (broadcasting)Electromagnetic compatibilityElectronic engineeringSimulationMedicineEngineeringTelecommunicationsRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Parallel radiofrequency transmission (pTx) remains a promising technology for addressing high-field magnetic resonance imaging (MRI) challenges, particularly regarding the safety of patients with implanted deep brain stimulation (DBS) devices. Radiofrequency (RF) shim optimization methods utilizing pTx technology have shown the potential to minimize induced RF heating effects at the electrode tips of DBS devices at 3 T. PURPOSE: Research pTx system implementations often involve the combination of custom and commercial hardware that are integrated onto an existing MRI system. As a result, system characterization is important to ensure implant-friendly safe imaging conditions are satisfied for the operating range of the hardware. METHODS: Utilizing electromagnetic and thermal simulations, the impact of system uncertainty is studied for the proposed 4- and 8-channel pTx system setup and its associated "safe mode" for DBS applications. RESULTS: Electromagnetic simulations indicated that instrumentation errors can affect the overall electric field strength experienced at the DBS lead tip, and a worst-case system uncertainty analysis predicted temperature elevations of +1.5°C in the 4-channel setup and +0.9°C in the 8-channel setup. CONCLUSIONS: In conclusion, system uncertainty can impact the precision of pTx RF inputs which in the worst-case, may lead to an unsafe imaging scenario and the proposed 8-channel setup may provide more robustness and thus, safer conditions for MRI of DBS patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.005
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.306
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicNeurological disorders and treatments→French-language works237,207→