Fracture resistance of zirconia surveyed crowns with four different occlusal rest seat designs
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
PURPOSE: To determine the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) zirconia surveyed crowns for a mandibular first molar without occlusal rest and with four different rest seat designs. MATERIALS AND METHODS: Seventy CAD-CAM zirconia 4Y-PSZ (IPS e.max ZirCAD MT for CEREC A1, C15, Ivoclar Vivadent) crowns (14 specimens/group) were designed and fabricated with a dental chairside CAD-CAM system (CEREC PrimeScan, and CEREC MCXL Dentsply Sirona). The restorations were divided into groups according to the following rest seat designs: (1) Surveyed crown without rest seat, (2) surveyed crowns with disto-occlusal rest seat, (3) surveyed crowns with disto-occlusal extended rest seat, (4) surveyed crowns with interproximal rest seat, and (5) continuous rest seat. Crowns were treated with a primer system (Monobond Plus, Ivoclar Vivadent) and cemented using resin luting cement (Multilink Automix, Ivoclar Vivadent) to resin-printed dies (Grey Resin V4, FormLabs). Subsequently, the crowns were subjected to 200,000 load cycles at 1 Hz with 20 N force and then loaded with a steel indenter until fracture. The test results were analyzed with one-way Analysis of Variance (ANOVA) and HSD Tukey post-Hoc test. RESULTS: The mean fracture resistance of surveyed crowns without and with different rest seats was significantly different from each other. Surveyed crowns with no rest seat displayed the highest resistance (4238 N) followed by crowns with continuous rest seat (3601 N), crowns with disto-occlusal extended rest seat (3283 N), and crowns with disto-occlusal rest seat (3257 N). Crowns with interproximal rest seat displayed the lowest fracture resistance (2723 N). CONCLUSIONS: Surveyed crowns without rest seats had a higher fracture resistance than crowns with rest seats Surveyed crowns with interproximal rest seats presented the lowest fracture resistance among all rest seat designs. Crowns with disto-occlusal rest seats, disto-occlusal extended rest seats, and continuous rest seats displayed similar fracture resistance.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it