MétaCan
Menu
Back to cohort
Record W4385191016 · doi:10.1016/j.jseint.2023.06.023

Implications of humeral short-stem diametral sizing on implant stability

2023· article· en· W4385191016 on OpenAlexafffund
Jacob M. Reeves, Gregory W. Spangenberg, Josie Elwell, Ben Stewart, Christopher Roche, Kenneth J. Faber, G. Daniel G. Langohr

Bibliographic record

VenueJSES International · 2023
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsHand and Upper Limb ClinicWestern University
FundersNatural Sciences and Engineering Research Council of CanadaMitacs
KeywordsCadaveric spasmStiffnessImplantStress shieldingInitial stabilityOrthodonticsBiomedical engineeringStem cellMedicineMaterials scienceFemurSurgeryComposite materialBiology

Abstract

fetched live from OpenAlex

Background Shoulder arthroplasty humeral stem design has evolved to include various shapes, coatings, lengths, sizes, and fixation methods. While necessary to accommodate patient anatomy characteristics, this creates a surgical paradox of choice. The relationship between the surgeon's selection of short-stem implant size and construct stiffness, resistance to subsidence and micromotion has not been assessed. Methods Eight paired cadaveric humeri were reconstructed with surgeon-selected (SS) and 2-mm diametrically larger (SS+2) short-stemmed press-fit implants. Each reconstruction was subjected to 2000 cycles of 90° forward flexion loading, and stem subsidence and micromotion were measured using optical tracking. Compressive stiffness of the stem-bone reconstruction was then assessed by applying a load in-line with the stem axis that resulted in 5 mm of stem subsidence. Results Increasing stem size by 2 mm resulted in the construct stiffness more than doubling compared to SS stems (−741 ± 243 N/mm vs. −334 ± 120 N/mm; P = .003; power = 0.971). These larger stems also subsided significantly less than their SS counterparts (SS: 1.2 ± 0.6 mm; SS+2: 0.5 ± 0.5 mm; P = .029; power = 0.66), though there were no significant changes in micromotion (SS: 169 ± 59 μm; SS+2: 187 ± 52 μm; P = .506; power = 0.094). Conclusions The results of this study highlight the importance of proper short-stem sizing, as a relatively small 2 mm increase in diametral size was observed to significantly impact construct stiffness, which could increase the risk of stress shielding and implant loosening. Future work should focus on developing tools that objectively quantify bone quality and aid surgeons in selecting the appropriate size short-stem humeral implants for a particular patient.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.397
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueJSES InternationalSame topicShoulder Injury and TreatmentFrench-language works237,207