MétaCan
Menu
Back to cohort
Record W4385221959 · doi:10.2147/opth.s412847

The Current Burden and Future Solutions for Preoperative Cataract-Refractive Evaluation Diagnostic Devices: A Modified Delphi Study

2023· article· en· W4385221959 on OpenAlexaff
Bonnie An Henderson, Jaime Aramberri, Robin Vann, Adi Abulafia, M. Ainslie-Garcia, John P. Berdahl, Nicole Ferko, Kjell Gunnar Gundersen, So Goto, Preeya K. Gupta, Samuel Multack, Elizabeth Persaud, Duna Raoof, Giacomo Savini, H. John Shammas, Li Wang, Wendy Zhi Wang

Bibliographic record

VenueClinical ophthalmology · 2023
Typearticle
Languageen
FieldMedicine
TopicIntraocular Surgery and Lenses
Canadian institutionsEVERSANA (Canada)
Fundersnot available
KeywordsMedicineOptometryDelphi methodCataract surgeryMedical physicsOphthalmologyComputer scienceArtificial intelligence

Abstract

fetched live from OpenAlex

Purpose: To obtain consensus on the key areas of burden associated with existing devices and to understand the requirements for a comprehensive next-generation diagnostic device to be able to solve current challenges and provide more accurate prediction of intraocular lens (IOL) power and presbyopia correction IOL success. Patients and Methods: Thirteen expert refractive cataract surgeons including three steering committee (SC) members constituted the voting panel. Three rounds of voting included a Round 1 structured electronic questionnaire, Round 2 virtual face-to-face meeting, and Round 3 electronic questionnaire to obtain consensus on topics related to current limitations and future solutions for preoperative cataract-refractive diagnostic devices. Results: Forty statements reached consensus including current limitations (n = 17) and potential solutions (n = 23) associated with preoperative diagnostic devices. Consistent with existing evidence, the panel reported unmet needs in measurement accuracy and validation, IOL power prediction, workflow, training, and surgical planning. A device that facilitates more accurate corneal measurement, effective IOL power prediction formulas for atypical eyes, simplified staff training, and improved decision-making process for surgeons regarding IOL selection is expected to help alleviate current burdens. Conclusion: Using a modified Delphi process, consensus was achieved on key unmet needs of existing preoperative diagnostic devices and requirements for a comprehensive next-generation device to provide better objective and subjective outcomes for surgeons, technicians, and patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.008
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.708
Threshold uncertainty score0.957

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.194
GPT teacher head0.476
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueClinical ophthalmologySame topicIntraocular Surgery and LensesFrench-language works237,207