MétaCan
Menu
Back to cohort
Record W4385552411 · doi:10.21926/jept.2303026

Volt-Var Control for Utility-Scale Solar PV Plants to Downsize SVCs and Curtailment Effects

2023· article· en· W4385552411 on OpenAlexaff
Ken Shimomukai, Haruka Maeda, Zahirah binti Muhammad Azman, Sandro Sitompul, Goro Fujita

Bibliographic record

VenueJournal of Energy and Power Technology · 2023
Typearticle
Languageen
FieldEngineering
TopicSmart Grid Energy Management
Canadian institutionsMorgan Solar (Canada)
Fundersnot available
KeywordsPhotovoltaic systemOvervoltageAC powerVoltageCompensation (psychology)Voltage regulationGridVoltage optimisationPhotovoltaicsVoltElectrical engineeringAutomotive engineeringControl theory (sociology)Computer scienceEngineeringControl (management)Mathematics

Abstract

fetched live from OpenAlex

One way to increase solar photovoltaic penetration in the grid is the management of voltage fluctuations. This is because a photovoltaic plant cannot be interconnected to the grid if it causes voltage violations. Voltage violation is where voltage exceeds the acceptable range. Often, grid operators request photovoltaic plant owners to regulate voltage sufficiently with expensive and space-consuming static Var compensators. Unfortunately, this sometimes makes the project less feasible. This paper argues that there are better ways to regulate voltage. It also asserts that these ways must be sought before blindly procuring a static Var compensator or seeking battery storage. We simulated with a 70-MW photovoltaic plant as an addition to the grid. Without voltage regulation, voltage violations in Spring were found to be particularly significant. However, the proposed reactive power compensation removed all voltage violations smartly. Furthermore, the study results demonstrated that the operator-induced curtailment effectively reduced the necessary amount of reactive power compensation, leading to a smaller size of SVC, as it occurred specifically at certain overvoltage points. This paper argues that the economic and spatial efficiency of reactive power compensation devices is key to increasing photovoltaic penetration. It argues that one-sided bearing of the cost of reactive compensation devices is inefficient.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.197
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Energy and Power TechnologySame topicSmart Grid Energy ManagementFrench-language works237,207