MétaCan
Menu
Back to cohort
Record W4385626942 · doi:10.1109/tia.2023.3302836

Hybrid Machine Learning-Based Intelligent Distance Protection and Control Schemes With Fault and Zonal Classification Capabilities for Grid- Connected Wind Farms

2023· article· en· W4385626942 on OpenAlexaff
M. Nasir Uddin, Nima Rezaei, Md. Shamsul Arifin

Bibliographic record

VenueIEEE Transactions on Industry Applications · 2023
Typearticle
Languageen
FieldEngineering
TopicPower Systems Fault Detection
Canadian institutionsLakehead University
Fundersnot available
KeywordsWind powerEngineeringRelayConvertersFault (geology)Electric power systemProtective relaySupport vector machineComputer scienceElectric power transmissionGridController (irrigation)Control theory (sociology)Reliability engineeringPower (physics)VoltageElectrical engineeringArtificial intelligenceControl (management)

Abstract

fetched live from OpenAlex

The poor performance of distance relays may stem from the inherently intermittent nature of wind power generation, presence of power electronic converters, the impact of power system harmonics, existence of series-compensated transmission lines, uncertainty of fault resistance, etc., which may adversely impact the performance of the distance protection relays. Thus, the distance relays in wind farms became a significant concern for utilities committed to ensuring compliance to the grid codes such as voltage-ride through capability and provide a stable and reliable power to the customers. Specialized algorithms, intelligent controllers, and advance monitoring systems must be developed to address these issues. Therefore, this article presents the analysis of several hybrid intelligent protection and control algorithms to improve the reliability of doubly fed induction generator (DFIG)-based wind farms during faults, and other dynamic operating conditions. First, a decision tree (DT) classification algorithm is developed as a fault classifier for the purpose of distinguishing between different types of faults, as well as normal operation and grid disturbances. Next, a support vector machine (SVM) as a fault location estimator and zonal protection scheme is proposed to assist with the decision-making process of distance relay by detecting the location of any type of fault on the transmission line, and precise line zoning protection with a high reliability. Lastly, a combined direct PI control-based scheme is developed for both rotor and grid side converters of the DFIG based wind energy conversion system (WECS). This scheme avoids extra PI based current loop to achieve robust performance at the time of grid side voltage dip as well as normal operating condition. The analysis of the proposed intelligent protection and control schemes exhibits satisfactory results in improving the reliability and stability of grid-connected wind farms.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.232
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Industry ApplicationsSame topicPower Systems Fault DetectionFrench-language works237,207