MétaCan
Menu
Back to cohort
Record W4385666620 · doi:10.1097/scs.0000000000009566

Accuracy of Orbital Shape Reconstruction—Comparative Analysis of Errors in Implant Shape Versus Implant Positioning: A Cadaveric Study

2023· article· en· W4385666620 on OpenAlexaff
Michael Hardisty, Yuan Tao Wei, Rayisa Hontscharuk, A. El Ibrahimi, Oleh Antonyshyn, Glenn Edwards, James G. Mainprize, Cari Whyne

Bibliographic record

VenueJournal of Craniofacial Surgery · 2023
Typearticle
Languageen
FieldMedicine
TopicFacial Trauma and Fracture Management
Canadian institutionsHealth Sciences CentreMuscular Dystrophy CanadaUniversity of TorontoSunnybrook HospitalSunnybrook Health Science Centre
Fundersnot available
KeywordsCadaveric spasmImplantMedicineEnophthalmosDiplopiaCADOrbit (dynamics)OrthodonticsProsthesis ImplantationDentistryProsthesisSurgeryEngineering drawing

Abstract

fetched live from OpenAlex

INTRODUCTION: Orbital blowout fractures are commonly reconstructed with implants shaped to repair orbital cavity defects, restore ocular position and projection, and correct diplopia. Orbital implant shaping has traditionally been performed manually by surgeons, with more recent use of computer-assisted design (CAD). Accuracy of implant placement is also key to reconstruction. This study compares the placement accuracy of orbital implants, testing the hypothesis that CAD-shaped implants indexed to patient anatomy will better restore orbit geometry compared with manually shaped implants and manually placed implants. METHODS: The placement accuracy of orbital implants was assessed within a cadaveric blowout fracture model (3 skulls, 6 orbits) via 3-dimensional CT analysis. Defects were repaired with 4 different techniques: manually placed-manually shaped composite (titanium-reinforced porous polyethylene), manually placed CAD composite, indexed placed CAD composite, and indexed placed CAD titanium mesh. RESULTS: Implant placement accuracy differed significantly with the implant preparation method ( P =0.01). Indexing significantly improved the placement accuracy ( P =0.002). Indexed placed titanium mesh CAD implants (1.42±0.33 mm) were positioned significantly closer to the intact surface versus manually placed-manually shaped composite implants (2.12±0.39 mm). DISCUSSION: Computer-assisted design implants indexed to patient geometry yielded average errors below the acceptable threshold (2 mm) for enophthalmos and diplopia. This study highlights the importance of adequately indexing CAD-designed implants to patient geometry to ensure accurate orbital reconstructions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.068
Threshold uncertainty score0.664

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.342
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Craniofacial SurgerySame topicFacial Trauma and Fracture ManagementFrench-language works237,207