MétaCan
Menu
Back to cohort
Record W4385732092 · doi:10.2106/jbjs.st.22.00023

Revision Total Hip Arthroplasty with a Modular Fluted Tapered Stem for a Periprosthetic Femoral Fracture

2023· article· en· W4385732092 on OpenAlexaboutno aff
Charles P. Hannon, Matthew P. Abdel

Bibliographic record

VenueJBJS Essential Surgical Techniques · 2023
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticMedicineFemoral canalImplantSurgeryFixation (population genetics)Femoral fractureArthroplastyFemurDentistry

Abstract

fetched live from OpenAlex

Background: As the number of primary total hip arthroplasty procedures performed each year continues to rise, so too do the number of complications, including periprosthetic femoral fracture 1–9 . Vancouver B2 and B3 periprosthetic femoral fractures are difficult to treat because they require the surgeon to simultaneously manage a femoral fracture and gain new implant fixation. Fluted tapered stems have advanced the treatment of periprosthetic femoral fractures by providing immediate axial and rotational implant fixation distal to the fracture 10–18 . Modular fluted tapered stems provide the added practical advantage of allowing length and anteversion adjustment after implantation of the distal fixation portion of the stem. Description: In this technique, a modified extended trochanteric osteotomy incorporating the fracture is utilized to gain access to the loose femoral implant and femoral diaphyseal canal. The femoral diaphyseal canal is then sequentially reamed in 1-mm increments. A fluted tapered stem with the appropriate length, diameter, and axial and rotational stability is inserted into the canal. A proximal body is then chosen that establishes the appropriate leg length, femoral offset, and version. The final proximal body is engaged into the fluted tapered stem. Finally, the fracture is fixed around the implant with a combination of cables or wires. Alternatives: Historically, implants such as extensively porous coated stems were utilized to treat Vancouver B2 or B 3 periprosthetic femoral fractures. Unfortunately, these implants were associated with high rates of failure and revision 7,9 . Rationale: The introduction of a fluted tapered stem provided a more reliable implant that achieves immediate axial and rotational stability. In addition, utilizing a fluted tapered stem allowed for a more soft-tissue-preserving approach to these complex injuries, in turn allowing the fracture to be reduced around the implant proximally with cerclage cables and or wires. Modular fluted tapered stems provide the additional advantage of allowing the surgeon to modify leg length, offset, and femoral version, independently of the fluted tapered stem. As a result of these unique advantages, these stems were introduced several years ago for the treatment of Vancouver B 2 or B 3 periprosthetic femoral fractures. Expected Outcomes: Contemporary series have demonstrated that the use of a modular fluted tapered stem leads to improved implant survivorship and clinical outcomes with lower complication rates for Vancouver B2 and B 3 periprosthetic femoral fractures 1,10–12,14–19 . Important Tips: Template both the fluted tapered stem and proximal body preoperatively. The proximal body should be templated at the ideal hip center of rotation that appropriately restores leg lengths and offset. Template the fluted tapered stem so that it provides appropriate isthmic fit and bypasses the most distal extent of the fracture by at least 2 cortical diameters. Utilize a modified extended trochanteric osteotomy for your exposure in order to facilitate visualization of the fracture and to provide direct access to the femoral canal. Place a prophylactic cable prior to preparing the femur for the implant in order to help prevent iatrogenic fracture. Place a trial stem and obtain intraoperative anteroposterior and lateral radiographs in order to assess the position of the implants and the risk of anterior cortical perforation. When placing the final implants, be sure the fluted tapered stem has both axial and rotational stability. Reduce and fix the fracture after the final implants are placed and the hip is reduced. Acronyms and Abbreviations: AP = anteroposterior MFT = modular fluted tapered (stem) ETO = extended trochanteric osteotomy THA = total hip arthroplasty CT = computed tomography PJI = periprosthetic joint infection

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.890
Threshold uncertainty score0.962

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.283
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJBJS Essential Surgical TechniquesSame topicOrthopaedic implants and arthroplastyFrench-language works237,207