MétaCan
Menu
Back to cohort
Record W4385755442 · doi:10.1139/apnm-2023-0149

Agreement between the ventilated capsule and the KuduSmart® device for measuring sweating responses to passive heat stress and exercise

2023· article· en· W4385755442 on OpenAlexafffundvenue
Nicholas Ravanelli, Douglas Newhouse, Fergus Foster, Aaron R. Caldwell

Bibliographic record

VenueApplied Physiology Nutrition and Metabolism · 2023
Typearticle
Languageen
FieldMedicine
TopicThermoregulation and physiological responses
Canadian institutionsLakehead UniversityLaurentian University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsLimits of agreementHeat stressSWEATForearmHeart rateSteady state (chemistry)ChemistryMaterials scienceMedicineAnimal scienceNuclear medicineSurgeryInternal medicine

Abstract

fetched live from OpenAlex

The present study assessed agreement between a wireless sweat rate monitor (KuduSmart® device) and the ventilated capsule (VC) technique for measuring: (i) minute-averaged local sweat rate (LSR), (ii) sweating onset, (iii) sudomotor thermosensitivity, and (iv) steady-state LSR, during passive heat stress and exercise. It was hypothesized that acceptable agreement with no bias would be observed between techniques for all assessed sweating characteristics. On two separate occasions for each intervention, participants were either passively heated by recirculating hot water (49 °C) through a tube-lined garment until rectal temperature increased 1 °C over baseline ( n = 8), or a 60 min treadmill march at a fixed rate of heat production (∼500 W, n = 9). LSR of the forearm was concurrently measured with a VC and the KuduSmart® device secured within ∼2 cm. Using a ratio scale Bland–Altman analysis with the VC as the reference, the KuduSmart® device demonstrated systematic bias and not acceptable agreement for minute-averaged LSR (1.17 [1.09, 1.27], CV = 44.5%), systematic bias and acceptable agreement for steady-state LSR (1.16 [1.09,1.23], CV = 19.5%), no bias and acceptable agreement for thermosensitivity (1.07 [0.99, 1.16], CV = 23.2%), and no bias and good agreement for sweating onset (1.00 [1.00, 1.00], CV = 11.1%). In total, ≥73% of all minute-averaged LSR observations with the KuduSmart® device ( n = 2743) were within an absolute error of <0.2 mg/cm 2 /min to the VC, the reference minimum detectable change in measurement error of a VC on the forearm. Collectively, the KuduSmart® device may be a satisfactory solution for assessing the sweating response to heat stress where a VC is impractical.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.028
metaresearch head score (Gemma)0.057
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score0.150

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0280.057
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.297
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes3
Has abstractyes

Explore more

Same venueApplied Physiology Nutrition and MetabolismSame topicThermoregulation and physiological responsesFrench-language works237,207