MétaCan
Menu
Back to cohort
Record W4385827226 · doi:10.2196/45504

Use of Wearable Devices for Peak Oxygen Consumption Measurement in Clinical Cardiology: Case Report and Literature Review

2023· article· en· W4385827226 on OpenAlexvenueno aff
Gabriella Bayshtok, Shmuel Tiosano, Ariel Furer

Bibliographic record

VenueInteractive Journal of Medical Research · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and exercise physiology
Canadian institutionsnot available
Fundersnot available
KeywordsWearable computerMedicineWearable technologyPopulationCardiologyIntensive care medicineComputer science

Abstract

fetched live from OpenAlex

Background Oxygen consumption is an important index to evaluate in cardiac patients, particularly those with heart failure, and is measured in the setting of advanced cardiopulmonary exercise testing. However, technological advances now allow for the estimation of this parameter in many consumer and medical-grade wearable devices, making it available for the medical provider at the initial evaluation of patients. We report a case of an apparently healthy male aged 40 years who presented for evaluation due to an Apple Watch (Apple Inc) notification of low cardiac fitness. This alert triggered a thorough workup, revealing a diagnosis of familial nonischemic cardiomyopathy with severely reduced left ventricular systolic function. While the use of wearable devices for the measurement of oxygen consumption and related parameters is promising, further studies are needed for validation. Objective The aim of this report is to investigate the potential utility of wearable devices as a screening and risk stratification tool for cardiac fitness for the general population and those with increased cardiovascular risk, particularly through the measurement of peak oxygen consumption (VO2). We discuss the possible advantages of measuring oxygen consumption using wearables and propose its integration into routine patient evaluation and follow-up processes. With the current evidence and limitations, we encourage researchers and clinicians to explore bringing wearable devices into clinical practice. Methods The case was identified at Sheba Medical Center, and the patient’s cardiac fitness was monitored through an Apple Watch Series 6. The patient underwent a comprehensive cardiac workup following his presentation. Subsequently, we searched the literature for articles relating to the clinical utility of peak VO2 monitoring and available wearable devices. Results The Apple Watch data provided by the patient demonstrated reduced peak VO2, a surrogate index for cardiac fitness, which improved after treatment initiation. A cardiological workup confirmed familial nonischemic cardiomyopathy with severely reduced left ventricular systolic function. A review of the literature revealed the potential clinical benefit of peak VO2 monitoring in both cardiac and noncardiac scenarios. Additionally, several devices on the market were identified that could allow for accurate oxygen consumption measurement; however, future studies and approval by the Food and Drug Administration (FDA) are still necessary. Conclusions This case report highlights the potential utility of peak VO2 measurements by wearable devices for early identification and screening of cardiac fitness for the general population and those at increased risk of cardiovascular disease. The integration of wearable devices into routine patient evaluation may allow for earlier presentation in the diagnostic workflow. Cardiac fitness can be serially measured using the wearable device, allowing for close monitoring of functional capacity parameters. Devices need to be used with caution, and further studies are warranted.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0080.008
Science and technology studies0.0010.002
Scholarly communication0.0020.003
Open science0.0020.001
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.302
GPT teacher head0.529
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueInteractive Journal of Medical ResearchSame topicCardiovascular and exercise physiologyFrench-language works237,207