MétaCan
Menu
Back to cohort
Record W4386102149 · doi:10.1016/j.clinph.2023.08.009

Targeted density electrode placement achieves high concordance with traditional high-density EEG for electrical source imaging in epilepsy

2023· article· en· W4386102149 on OpenAlexafffund
Alejandro Horrillo‐Maysonnial, Tamir Avigdor, Chifaou Abdallah, Daniel Mansilla, John Thomas, Nicolás von Ellenrieder, Jessica Royer, Boris C. Bernhardt, Christophe Grova, Jean Gotman, Birgit Frauscher

Bibliographic record

VenueClinical Neurophysiology · 2023
Typearticle
Languageen
FieldMedicine
TopicEpilepsy research and treatment
Canadian institutionsConcordia UniversityMcGill UniversityMontreal Neurological Institute and Hospital
FundersCanadian Institutes of Health Research
KeywordsElectroencephalographyConcordanceEpilepsyElectrodeComputer scienceAudiologyMedicinePsychologyNeurosciencePhysicsInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: High-density (HD) electroencephalography (EEG) is increasingly used in presurgical epilepsy evaluation, but it is demanding in time and resources. To overcome these issues, we compared EEG source imaging (ESI) solutions with a targeted density and HD-EEG montage. METHODS: HD-EEGs from patients undergoing presurgical evaluation were analyzed. A low-density recording was created by selecting the 25 electrodes of a standard montage from the 83 electrodes of the HD-EEG and adding 8-11 electrodes around the electrode with the highest amplitude interictal epileptiform discharges. The ESI solution from this "targeted" montage was compared to that from the HD-EEG using the distance between peak vertices, sublobar concordance and a qualitative similarity measure. RESULTS: Fifty-eight foci of forty-three patients were included. The median distance between the peak vertices of the two montages was 13.2 mm, irrespective of focus' location. Tangential generators (n = 5/58) showed a higher distance than radial generators (p = 0.04). We found sublobar concordance in 54/58 of the foci (93%). Map similarity, assessed by an epileptologist, had a median score of 4/5. CONCLUSIONS: ESI solutions obtained from a targeted density montage show high concordance with those calculated from HD-EEG. SIGNIFICANCE: Requiring significantly fewer electrodes, targeted density EEG allows obtaining similar ESI solutions as traditional HD-EEG montage.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.257
Threshold uncertainty score0.837

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.331
Teacher spread0.292 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueClinical NeurophysiologySame topicEpilepsy research and treatmentFrench-language works237,207