MétaCan
Menu
Back to cohort
Record W4386155110 · doi:10.1088/1361-6560/acf439

Evaluation of MR anatomically-guided PET reconstruction using a convolutional neural network in PSMA patients

2023· article· en· W4386155110 on OpenAlexaff
Adam Farag, Jin Huang, Andrés Kohan, Seyed Ali Mirshahvalad, Adriano Basso Dias, Matthias Fenchel, Ur Metser, Patrick Veit‐Haibach

Bibliographic record

VenuePhysics in Medicine and Biology · 2023
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity Health Network
Fundersnot available
KeywordsConvolutional neural networkImaging phantomMagnetic resonance imagingNuclear medicinePositron emission tomographyPartial volumeCorrection for attenuationArtificial intelligenceIterative reconstructionComputer scienceImage qualityPattern recognition (psychology)MedicineRadiologyImage (mathematics)

Abstract

fetched live from OpenAlex

Abstract Background . Recently, approaches have utilized the superior anatomical information provided by magnetic resonance imaging (MRI) to guide the reconstruction of positron emission tomography (PET). One of those approaches is the Bowsher’s prior, which has been accelerated lately with a convolutional neural network (CNN) to reconstruct MR-guided PET in the imaging domain in routine clinical imaging. Two differently trained Bowsher-CNN methods (B-CNN0 and B-CNN) have been trained and tested on brain PET/MR images with non-PSMA tracers, but so far, have not been evaluated in other anatomical regions yet. Methods . A NEMA phantom with five of its six spheres filled with the same, calibrated concentration of 18F-DCFPyL-PSMA, and thirty-two patients (mean age 64 ± 7 years) with biopsy-confirmed PCa were used in this study. Reconstruction with either of the two available Bowsher-CNN methods were performed on the conventional MR-based attenuation correction (MRAC) and T 1 -MR images in the imaging domain. Detectable volume of the spheres and tumors, relative contrast recovery (CR), and background variation (BV) were measured for the MRAC and the Bowsher-CNN images, and qualitative assessment was conducted by ranking the image sharpness and quality by two experienced readers. Results . For the phantom study, the B-CNN produced 12.7% better CR compared to conventional reconstruction. The small sphere volume (<1.8 ml) detectability improved from MRAC to B-CNN by nearly 13%, while measured activity was higher than the ground-truth by 8%. The signal-to-noise ratio, CR, and BV were significantly improved ( p < 0.05) in B-CNN images of the tumor. The qualitative analysis determined that tumor sharpness was excellent in 76% of the PET images reconstructed with the B-CNN method, compared to conventional reconstruction. Conclusions . Applying the MR-guided B-CNN in clinical prostate PET/MR imaging improves some quantitative, as well as qualitative imaging measures. The measured improvements in the phantom are also clearly translated into clinical application.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.355
GPT teacher head0.472
Teacher spread0.117 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207