Aseptic survival of the 1.5‐stage exchange arthroplasty for periprosthetic joint infection was acceptable when using an autoclaved femoral component and a new polyethylene insert
Bibliographic record
Abstract
PURPOSE: To investigate the aseptic survival of 1.5-stage exchange arthroplasty for periprosthetic joint infection (PJI) after total knee arthroplasty (TKA). METHODS: Eighty-eight cases of 1.5-stage exchange arthroplasty for PJI without reinfection were retrospectively analysed. The autoclaved femoral component and new polyethylene insert (PE) were implanted using antibiotic mixed cement. The explanted tibial component was not reinserted. The Western Ontario and McMaster Universities Osteoarthritis Index and range of motion were clinically evaluated preoperatively and at the last follow-up (the last time for the implant in situ). Radiographically, hip-knee-ankle angle (HKA) and component positions were measured preoperatively, postoperatively (1 month after the 1.5-stage exchange arthroplasty), and at the last follow-up. The survival rate was analysed using the Kaplan-Meier method, in which failure was defined as reoperation due to aseptic failure. Mean period to failure and failure site were analysed. Factors affecting survival were investigated in terms of demographics and inappropriateness of the postoperative HKA (HKA > 0 ± 3°) and component positions (α angle > 95 ± 3°, β angle > 90 ± 3°, γ angle > 3 ± 3°, and δ angle > 87 ± 3°). RESULTS: The spacer in-situ time was 3.7 years (0.2-6.4). The clinical results improved hip-knee-ankle significantly at the last follow-up. Radiographically, the average HKA was valgus 0.1° postoperatively. The average α, β, γ, and δ angles of the postoperative component positions were 95.9°, 90.4°, 3.8°, and 86.7°, respectively. The 1-, 2-, and 5-year postoperative survival rates were 90.9%, 86.4%, and 80.6%, respectively. The mean period to failure was 2.0 years (0.2-5.3). There were 18 cases of aseptic loosening (20.8%), occurring on both the femur and tibial sides in 1 knee, and only on the tibial side in 17 knees. Inappropriate coronal position of the PE (β angle > 90 ± 3°) was a significant factor affecting survival (odds ratio = 5.491; p = 0.011). CONCLUSION: The aseptic survival of the 1.5-stage exchange arthroplasty was acceptable when using an autoclaved femoral component and new PE. The appropriate coronal position of the PE helps ensure favourable survival of 1.5-stage exchange arthroplasty. LEVEL OF EVIDENCE: IV.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.003 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".