MétaCan
Menu
Back to cohort
Record W4386400984 · doi:10.1101/2023.08.31.23294891

Application of MALDI-MS and Machine Learning to Detection of SARS-CoV-2 and non-SARS-CoV-2 Respiratory Infections

2023· preprint· en· W4386400984 on OpenAlexaff
Sergey Yegorov, Irina Kadyrova, Ilya Korshukov, Aidana Sultanbekova, Valentina Barkhanskaya, Tatiana Bashirova, Yerzhan Zhunusov, Yevgeniya Li, Viktoriya Parakhina, Svetlana Kolesnichenko, Yeldar Baiken, Bakhyt Matkarimov, Dmitriy Vazenmiller, Matthew S. Miller, Gonzalo Hortelano, Anar Turmuhambetova, Antonella Cheşcă, Dmitriy Babenko

Bibliographic record

VenuemedRxiv · 2023
Typepreprint
Languageen
FieldEngineering
TopicAdvanced Chemical Sensor Technologies
Canadian institutionsMcMaster UniversityMcMaster University Medical Centre
Fundersnot available
KeywordsSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)AsymptomaticCoronavirus disease 2019 (COVID-19)Matrix-assisted laser desorption/ionizationMedicineMass spectrometryRespiratory systemInternal medicineChromatographyChemistry

Abstract

fetched live from OpenAlex

Abstract Background Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) could aid the diagnosis of acute respiratory infections (ARI) owing to its affordability and high-throughput capacity. MALDI-MS has been proposed for use on commonly available respiratory samples, without specialized sample preparation, making this technology especially attractive for implementation in low-resource regions. Here, we assessed the utility of MALDI-MS in differentiating SARS-CoV-2 versus non-COVID acute respiratory infections (NCARI) in a clinical lab setting of Kazakhstan. Methods Nasopharyngeal swabs were collected from in- and outpatients with respiratory symptoms and from asymptomatic controls (AC) in 2020-2022. PCR was used to differentiate SARS-CoV-2+ and NCARI cases. MALDI-MS spectra were obtained for a total of 252 samples (115 SARS-CoV-2+, 98 NCARI and 39 AC) without specialized sample preparation. In our first sub-analysis, we followed a published protocol for peak preprocessing and Machine Learning (ML), trained on publicly available spectra from South American SARS-CoV-2+ and NCARI samples. In our second sub-analysis, we trained ML models on a peak intensity matrix representative of both South American (SA) and Kazakhstan (Kaz) samples. Results Applying the established MALDI-MS pipeline ”as is” resulted in a high detection rate for SARS-CoV-2+ samples (91.0%), but low accuracy for NCARI (48.0%) and AC (67.0%) by the top-performing random forest model. After re-training of the ML algorithms on the SA-Kaz peak intensity matrix, the accuracy of detection by the top-performing Support Vector Machine with radial basis function kernel model was at 88.0, 95.0 and 78% for the Kazakhstan SARS-CoV-2+, NCARI, and AC subjects, respectively with a SARS-CoV-2 vs. rest ROC AUC of 0.983 [0.958, 0.987]; a high differentiation accuracy was maintained for the South American SARS-CoV-2 and NCARI. Conclusions MALDI-MS/ML is a feasible approach for the differentiation of ARI without a specialized sample preparation. The implementation of MALDI-MS/ML in a real clinical lab setting will necessitate continuous optimization to keep up with the rapidly evolving landscape of ARI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.060
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.282
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venuemedRxivSame topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207