MétaCan
Menu
Back to cohort
Record W4386531019 · doi:10.1088/1361-6560/acf111

Improved sub-milimeter range-verification method for proton therapy using a composite hadron tumour marker (HTM)

2023· article· en· W4386531019 on OpenAlexafffund
Eva Kasanda, C. Burbadge, V. Bildstein, C. Bélanger-Champagne, Hadi Behnamian, C. Höhr, D. Mücher

Bibliographic record

VenuePhysics in Medicine and Biology · 2023
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsTRIUMFUniversity of VictoriaUniversity of Guelph
FundersCanadian Institutes of Health Research
KeywordsProton therapyRange (aeronautics)Imaging phantomBeam (structure)ProtonMaterials scienceNuclear medicineDetectorStandard deviationBiomedical engineeringOpticsNuclear physicsPhysicsStatisticsMathematicsMedicineComposite material

Abstract

fetched live from OpenAlex

Abstract Objective. The results of a follow-up experiment investigating a novel method for sub-milimetre range verification (RV) in proton therapy (PT) are presented. Approach. The method consists of implanting a hadron tumour marker (HTM) near the planned treatment volume, and measuring the γ-ray signals emitted as a result of activation by the proton beam. These signals are highly correlated with the energy of the beam impinging on the HTM and can provide an absolute measurement of the range of the beam relative to the position of the HTM, which is independent of any uncertainties in beam delivery. Main results. Three candidate HTM materials were identified and combined into a single composite HTM, which makes use of the strongest reaction in each material. The setup of the previous experiment was improved on by using high-purity germanium detectors to measure the γ-ray signal with a higher resolution than was previously achieved. A PMMA phantom was also used to simulate the γ-ray background from tissue activation. HTM RV using the data collected in this study yielded range measurements whose average deviation from the expected value was 0.13(22)mm. Significance. Range uncertainty in PT limits the prescribed treatment plan for cancer patients with large safety margins and constrains the direction of the proton beam in relation to any organ at risk. The sub-milimetre range uncertainty achieved in this study using HTM RV, if implemented clinically, would allow for a reduction in the size of safety margins, increasing the therapeutic window for PT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.228
GPT teacher head0.445
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiation Therapy and DosimetryFrench-language works237,207