MétaCan
Menu
Back to cohort
Record W4386531233 · doi:10.1007/s00259-023-06418-7

Differential privacy preserved federated transfer learning for multi-institutional 68Ga-PET image artefact detection and disentanglement

2023· article· en· W4386531233 on OpenAlexafffund
Isaac Shiri, Yazdan Salimi, Mehdi Maghsudi, Elnaz Jenabi, Sara Harsini, Behrooz Razeghi, Shayan Mostafaei, Ghasem Hajianfar, Amirhossein Sanaat, Esmail Jafari, Rezvan Samimi, Maziar Khateri, Peyman Sheikhzadeh, Parham Geramifar, Habibollah Dadgar, Ahmad Bitrafan Rajabi, Majid Assadi, François Bénard, Alireza Vafaei Sadr, Slava Voloshynovskiy, Ismini Mainta, Carlos Uribe, Arman Rahmim, Habib Zaidi

Bibliographic record

VenueEuropean Journal of Nuclear Medicine and Molecular Imaging · 2023
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaUniversité de GenèveHôpitaux Universitaires de GenèveSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungNational Science Foundation
KeywordsDifferential privacyComputer scienceTransfer of learningDifferential (mechanical device)Image (mathematics)Artificial intelligenceData miningPhysics

Abstract

fetched live from OpenAlex

Abstract Purpose Image artefacts continue to pose challenges in clinical molecular imaging, resulting in misdiagnoses, additional radiation doses to patients and financial costs. Mismatch and halo artefacts occur frequently in gallium-68 ( 68 Ga)-labelled compounds whole-body PET/CT imaging. Correcting for these artefacts is not straightforward and requires algorithmic developments, given that conventional techniques have failed to address them adequately. In the current study, we employed differential privacy-preserving federated transfer learning (FTL) to manage clinical data sharing and tackle privacy issues for building centre-specific models that detect and correct artefacts present in PET images. Methods Altogether, 1413 patients with 68 Ga prostate-specific membrane antigen (PSMA)/DOTA-TATE (TOC) PET/CT scans from 3 countries, including 8 different centres, were enrolled in this study. CT-based attenuation and scatter correction (CT-ASC) was used in all centres for quantitative PET reconstruction. Prior to model training, an experienced nuclear medicine physician reviewed all images to ensure the use of high-quality, artefact-free PET images (421 patients’ images). A deep neural network (modified U2Net) was trained on 80% of the artefact-free PET images to utilize centre-based (CeBa), centralized (CeZe) and the proposed differential privacy FTL frameworks. Quantitative analysis was performed in 20% of the clean data (with no artefacts) in each centre. A panel of two nuclear medicine physicians conducted qualitative assessment of image quality, diagnostic confidence and image artefacts in 128 patients with artefacts (256 images for CT-ASC and FTL-ASC). Results The three approaches investigated in this study for 68 Ga-PET imaging (CeBa, CeZe and FTL) resulted in a mean absolute error (MAE) of 0.42 ± 0.21 ( CI 95%: 0.38 to 0.47), 0.32 ± 0.23 ( CI 95%: 0.27 to 0.37) and 0.28 ± 0.15 ( CI 95%: 0.25 to 0.31), respectively. Statistical analysis using the Wilcoxon test revealed significant differences between the three approaches, with FTL outperforming CeBa and CeZe ( p -value < 0.05) in the clean test set. The qualitative assessment demonstrated that FTL-ASC significantly improved image quality and diagnostic confidence and decreased image artefacts, compared to CT-ASC in 68 Ga-PET imaging. In addition, mismatch and halo artefacts were successfully detected and disentangled in the chest, abdomen and pelvic regions in 68 Ga-PET imaging. Conclusion The proposed approach benefits from using large datasets from multiple centres while preserving patient privacy. Qualitative assessment by nuclear medicine physicians showed that the proposed model correctly addressed two main challenging artefacts in 68 Ga-PET imaging. This technique could be integrated in the clinic for 68 Ga-PET imaging artefact detection and disentanglement using multicentric heterogeneous datasets.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.934
Threshold uncertainty score0.426

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.311
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueEuropean Journal of Nuclear Medicine and Molecular ImagingSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207