MétaCan
Menu
Back to cohort
Record W4386704366 · doi:10.1515/cclm-2023-0518

Development and multi-center validation of a fully automated digital immunoassay for neurofilament light chain: toward a clinical blood test for neuronal injury

2023· article· en· W4386704366 on OpenAlexaff
David H. Wilson, Dandan Chan, Lei Chang, R I Mathis, Inge M.W. Verberk, Xavier Montalbán, Manuel Comabella, Nicolás Fissolo, Bibi Bielekova, Ruturaj Masvekar, Tanuja Chitnis, Tjalf Ziemssen, Katja Akgün, Kaj Blennow, Henrik Zetterberg, Wolfgang Brück, Gavin Giovannoni, Sharmilee Gnanapavan, Stefan Bittner, Frauke Zipp, Gıancarlo Comı, Roberto Furlan, Sylvain Lehmann, Simon Thebault, Mark Freedman, Amit Bar‐Or, Marty Kramer, Markus Otto, Steffen Halbgebauer, Kevin Hrusovsky, Tatiana Plavina, Michael Khalil, Fredrik Piehl, Heinz Wiendl, Ludwig Kappos, Aleksandra Maleska Maceski, Eline A.J. Willemse, David Leppert, Charlotte E. Teunissen, Jens Kühle

Bibliographic record

VenueClinical Chemistry and Laboratory Medicine (CCLM) · 2023
Typearticle
Languageen
FieldMedicine
TopicMultiple Sclerosis Research Studies
Canadian institutionsOttawa HospitalUniversity of Ottawa
Fundersnot available
KeywordsImmunoassayReproducibilityBiomarkerMedicineMultiple sclerosisInternal medicineChromatographyImmunologyChemistry

Abstract

fetched live from OpenAlex

OBJECTIVES: Neurofilament light chain (NfL) has emerged as a promising biomarker for detecting and monitoring axonal injury. Until recently, NfL could only be reliably measured in cerebrospinal fluid, but digital single molecule array (Simoa) technology has enabled its precise measurement in blood samples where it is typically 50-100 times less abundant. We report development and multi-center validation of a novel fully automated digital immunoassay for NfL in serum for informing axonal injury status. METHODS: A 45-min immunoassay for serum NfL was developed for use on an automated digital analyzer based on Simoa technology. The analytical performance (sensitivity, precision, reproducibility, linearity, sample type) was characterized and then cross validated across 17 laboratories in 10 countries. Analytical performance for clinical NfL measurement was examined in individual patients with relapsing remitting multiple sclerosis (RRMS) after 3 months of disease modifying treatment (DMT) with fingolimod. RESULTS: The assay exhibited a lower limit of detection (LLoD) of 0.05 ng/L, a lower limit of quantification (LLoQ) of 0.8 ng/L, and between-laboratory imprecision <10 % across 17 validation sites. All tested samples had measurable NfL concentrations well above the LLoQ. In matched pre-post treatment samples, decreases in NfL were observed in 26/29 RRMS patients three months after DMT start, with significant decreases detected in a majority of patients. CONCLUSIONS: The sensitivity characteristics and reproducible performance across laboratories combined with full automation make this assay suitable for clinical use for NfL assessment, monitoring in individual patients, and cross-comparisons of results across multiple sites.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score0.072

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0140.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.117
GPT teacher head0.414
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueClinical Chemistry and Laboratory Medicine (CCLM)Same topicMultiple Sclerosis Research StudiesFrench-language works237,207