MétaCan
Menu
Back to cohort
Record W4386757868 · doi:10.1002/mp.16729

Technical note: Impact of dose voxel kernel (DVK) values on dosimetry estimates in <sup>177</sup>Lu and <sup>90</sup>Y radiopharmaceutical therapy (RPT) applications

2023· article· en· W4386757868 on OpenAlexaff
Rachele Danieli, D. Pistone, Jonathan Tranel, Francesca Botta, Carlos Uribe‐Munoz, Davide Raspanti, F. Salvat, S.J. Wilderman, Manuel Bardiès, Ernesto Amato, Yuni K. Dewaraja, Marta Cremonesi

Bibliographic record

VenueMedical Physics · 2023
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsUniversity of British ColumbiaBC Cancer Agency
FundersNational Cancer InstituteNational Institute of Biomedical Imaging and BioengineeringMinistero della Salute
KeywordsDosimetryVoxelNuclear medicineAbsorbed doseKernel (algebra)MedicineRadiation treatment planningMathematicsAlgorithmStatisticsRadiation therapyRadiologyCombinatorics

Abstract

fetched live from OpenAlex

Abstract Background Radiopharmaceutical therapy (RPT) is an increasingly adopted modality for treating cancer. There is evidence that the optimization of the treatment based on dosimetry can improve outcomes. However, standardization of the clinical dosimetry workflow still represents a major effort. Among the many sources of variability, the impact of using different Dose Voxel Kernels (DVKs) to generate absorbed dose (AD) maps by convolution with the time‐integrated activity (TIA) distribution has not been systematically investigated. Purpose This study aims to compare DVKs and assess the differences in the ADs when convolving the same TIA map with different DVKs. Methods DVKs of 3 × 3 × 3 mm 3 sampling—nine for 177 Lu, nine for 90 Y—were selected from those most used in commercial/free software or presented in prior publications. For each voxel within a 11 × 11 × 11 matrix, the coefficient of variation (CoV) and the percentage difference between maximum and minimum values (% maximum difference) were calculated. The total absorbed dose per decay (SUM), calculated as the sum of all the voxel values in each kernel, was also compared. Publicly available quantitative SPECT images for two patients treated with 177 Lu‐DOTATATE and PET images for two patients treated with 90 Y‐microspheres were used, including organs at risk ( 177 Lu: kidneys; 90 Y: liver and healthy liver) and tumors’ segmentations. For each patient, the mean AD to the volumes of interest (VOIs) was calculated using the different DVKs, the same TIA map and the same software tool for dose convolution, thereby focusing on the DVK impact. For each VOI, the % maximum difference of the mean AD between maximum and minimum values was computed. Results The CoV (% maximum difference) in voxels of normalized coordinates [0,0,0], [0,1,0], and [0,1,1] were 5%(21%), 9%(35%), and 10%(46%) for the 177 Lu DVKs. For the case of 90 Y, these values were 2%(9%), 4%(14%), and 4%(16%). The CoV (% maximum difference) for SUM was 9%(33%) for 177 Lu, and 4%(15%) for 90 Y. The variability of the mean tumor and organ AD was up to 19% and 15% in 177 Lu‐DOTATATE and 90 Y‐microspheres patients, respectively. Conclusions This study showed a considerable AD variability due exclusively to the use of different DVKs. A concerted effort by the scientific community would contribute to decrease these discrepancies, strengthening the consistency of AD calculation in RPT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.060
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.013
Threshold uncertainty score0.066

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.060
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.398
Teacher spread0.359 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207