Intrarenal Pressure Measured Using a Novel Flexible Ureteroscope with Pressure Sensing Capabilities: A Study of the Effects of Ureteral Access Sheath, Irrigation, and Working Channel Accessories

2023· article· en· W4386864030 on OpenAlexaff
Ben H. Chew, Nabil Shalabi, Roman Herout, Alina Reicherz, K.F. Victor Wong, Kyle Searles, Naeem Bhojani

Bibliographic record

VenueJournal of Endourology · 2023
Typearticle
Languageen
FieldMedicine
TopicKidney Stones and Urolithiasis Treatments
Canadian institutionsVancouver General HospitalCentre Hospitalier de l’Université de MontréalUniversity of British Columbia
Fundersnot available
KeywordsURETEROSCOPEMedicineUrologyBiomedical engineeringNuclear medicineSurgery

Abstract

fetched live from OpenAlex

Introduction: Intrarenal pressure is emerging as an important monitoring parameter during flexible ureteroscopy (fURS). We measure how intraoperative conditions affect intrarenal pressure using a novel pressure sensing ureteroscope. Methods: The LithoVue Elite (LVE) single-use digital flexible ureteroscope (Boston Scientific) is the first commercial ureteroscope that senses pressure at its tip. LVE was used in a porcine model to measure intrarenal pressure with and without a ureteral access sheath (UAS) with various sizes and placement locations, irrigation methods, and working channel accessories. LVE pressure accuracy was measured in a bench model. This abstract shows the least-square means from multiway analysis of variances used for analysis. Results: Intrarenal pressures were the highest without a UAS (64 mm Hg), followed by the 11/13 UAS (51 mm Hg) and the 12/14 and 13/15, which were not statistically different (39–40 mm Hg). The pressures were highest with UASs placed at the ureteropelvic junction (61 mm Hg), and lowest if placed in the renal pelvis (24 mm Hg). Irrigation methods showed the highest pressures with syringe (57 mm Hg), while irrigation bags (pressurized at 150–300 mm Hg) produced 43 to 46 mm Hg and 25 mm Hg when applied with 80 cm of gravity. Placing a 200 μm laser fiber reduced pressures from 44 to 41 mm Hg. Finally, the bench model showed that LVE was 96% accurate up to 300 mm Hg. Conclusion: Intrarenal pressure significantly varied based on UAS sizes, placement, and irrigation methods. Accordingly, fURS with LVE is poised to be an invaluable tool for clinical decision-making and future studies of intrarenal pressure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.034
Threshold uncertainty score0.502

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.308
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of EndourologySame topicKidney Stones and Urolithiasis TreatmentsFrench-language works237,207