MétaCan
Menu
Back to cohort
Record W4387033982 · doi:10.1007/s00590-023-03682-z

Perioperative periprosthetic femur fracture associated with direct anterior total hip arthroplasty using metaphyseal fit and fill stem

2023· article· en· W4387033982 on OpenAlexaboutno aff
Frederic Washburn, Jacob Mushaben, Clayton Eichenseer, Brent Sanderson, Britni Tran, Thomas Golden

Bibliographic record

VenueEuropean Journal of Orthopaedic Surgery & Traumatology · 2023
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticMedicineValgusFemurCalcarOrthopedic surgeryFemur fracturePerioperativeSurgeryFemoral neckArthroplastyDentistryOsteoporosisInternal medicine

Abstract

fetched live from OpenAlex

INTRODUCTION: This study aims to identify radiographic and clinical risk factors of perioperative periprosthetic femur fracture associated with the direct anterior approach (DAA) using a metaphyseal fit and fill stem. We hypothesize stem malalignment with this femoral implant places increased stress on the medial calcar region, which leads to an increased risk of periprosthetic fracture. METHODS: We compared patients with periprosthetic femur fractures following DAA total hip arthroplasty (THA) utilizing the Echo Bi-Metric Microplasty Stem (Zimmer Biomet, Warsaw, IN) to a cohort of patients who did not sustain a periprosthetic fracture from five orthopedic surgeons over four years. Postoperative radiographs were evaluated for stem alignment, neck cut level, Dorr classification, and the presence of radiographic pannus. Univariate and logistic regression analyses were performed. Demographic and categorical variables were also analyzed. RESULTS: Fourteen hips sustained femur fractures, including nine Vancouver B2 and five AG fractures. Valgus stem malalignment, proud stems, extended offset, and patients with enlarged radiographic pannus reached statistical significance for increased fracture risk. Low femoral neck cut showed a trend toward statistical significance. CONCLUSION: Patients undergoing DAA THA using a metaphyseal fit and fill stem may be at increased risk of perioperative periprosthetic fracture when the femoral stem sits proudly in valgus malalignment with extended offset and when an enlarged pannus is seen radiographically. This study identifies a specific pattern in the Vancouver B2 fracture cohort with regard to injury mechanism, time of injury, and fracture pattern, which may be attributed to coronal malalignment of the implant.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.261
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Orthopaedic Surgery & TraumatologySame topicOrthopaedic implants and arthroplastyFrench-language works237,207