MétaCan
Menu
Back to cohort
Record W4387074428 · doi:10.35366/112300

Causas anatómicas inusuales de malposición de catéteres venosos centrales

2023· article· es· W4387074428 on OpenAlexaff
Raquel Bascón-Ortega, José Ramón Giménez-Ciruela, Antonio Ontanilla-López, Bartolomé Fernández Torres

Bibliographic record

VenueRevista Mexicana de Anestesiología · 2023
Typearticle
Languagees
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsOptech (Canada)
Fundersnot available
KeywordsMedicine

Abstract

fetched live from OpenAlex

RESUMEN.La malposición de los catéteres venosos centrales se asocia a importantes riesgos, a menudo infraestimados.Aunque se han descrito algunos factores que pueden favorecer la malposición, generalmente su causa no llega a diagnosticarse y parece ser de origen multifactorial.Presentamos dos casos de malposición de catéteres venosos centrales motivadas por causas anatómicas inusuales, diagnosticadas en el perioperatorio.En el primer caso, se diagnostica una agenesia de vena cava superior en el transcurso de una sustitución mitral por esternotomía, que lógicamente se asocia con una malposición de la vía central insertada.La utilización de catéteres y dispositivos a través de venas yugulares y subclavias en pacientes con esta infrecuente patología implica importantes limitaciones y complicaciones potenciales graves.En el segundo caso, la existencia de un bocio no diagnosticado provoca la malposición bilateral y simultánea de dos catéteres venosos canalizados, en el contexto de una situación de emergencia, en ambas venas yugulares internas.ABSTRACT.Malposition of central venous catheters is associated with important and underestimated risks.Although some factors have been related with malposition, its cause is generally not diagnosed, and it seems to have multifactorial origin.We present two cases of central venous catheter malposition due to unusual anatomical causes, diagnosed in the perioperative period.In the first case, superior vena cava agenesis was diagnosed during mitral replacement by sternotomy, which was logically associated with malposition of the inserted central line.The use of catheters and devices through jugular and subclavian veins in patients with this infrequent pathology is associated with important limitations and serious potential complications.In the second case, an undiagnosed goiter causes bilateral and simultaneous malpositioning of two inserted central venous catheters, in the context of an emergency situation, in both internal jugular veins.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.372
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueRevista Mexicana de AnestesiologíaSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207