MétaCan
Menu
Back to cohort
Record W4387369162 · doi:10.1038/s41598-023-43945-7

Advancing chirality analysis through enhanced enantiomer characterization and quantification via fast Fourier transform capacitance voltammetry

2023· article· en· W4387369162 on OpenAlexafffund
Mehrnaz Ebrahimi, Parviz Norouzi, Jahan B. Ghasemi, Ali Akbar Moosavi‐Movahedi, Meissam Noroozifar, Razieh Salahandish

Bibliographic record

VenueScientific Reports · 2023
Typearticle
Languageen
FieldChemistry
TopicMolecular spectroscopy and chirality
Canadian institutionsThe Scarborough HospitalUniversity of TorontoYork University
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of TehranIran National Science FoundationNational Science Foundation
KeywordsFourier transformCyclic voltammetryCapacitanceCharacterization (materials science)EnantiomerVoltammetryChirality (physics)Analytical Chemistry (journal)Fourier analysisMaterials scienceChemistryNanotechnologyChromatographyPhysicsPhysical chemistryStereochemistryElectrodeElectrochemistry

Abstract

fetched live from OpenAlex

The exploration of the chiral configurations of enantiomers represents a highly intriguing realm of scientific inquiry due to the distinct roles played by each enantiomer (D and L) in chemical reactions and their practical utilities. This study introduces a pioneering analytical methodology, termed fast Fourier transform capacitance voltammetry (FFT-CPV), in conjunction with principal component analysis (PCA), for the identification and quantification of the chiral forms of tartaric acid (TA), serving as a representative model system for materials exhibiting pronounced chiral characteristics. The proposed methodology relies on the principle of chirality, wherein the capacitance signal generated by the adsorption of D-TA and L-TA onto the surface of a platinum electrode (Pt-electrode) in an acidic solution is harnessed. The capacitance voltammograms were meticulously recorded under optimized experimental conditions. To compile the final dataset for the analyte, the average of the FFT capacitance voltammograms of the acidic solution (without the presence of the analyte) was subtracted from those containing the analyte. A distinct arrangement was obtained by employing PCA as a linear data transformation method, representing D-TA and L-TA in a two/three-dimensional space. The outcomes of the study reveal the successful detection of the two chiral forms of TA with a considerable degree of precision and reproducibility. Moreover, the proposed method facilitated the establishment of two linear response ranges for the concentration values of each enantiomer, spanning from 1 to 20 µM, and 50 to 500 µM. The respective detection limits were also determined to be 0.4 µM for L-TA and 1.3 µM for D-TA. These findings underscore the satisfactory sensitivity and efficiency of the proposed method in both qualitative and quantitative assessments of the chiral forms of TA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.266
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueScientific ReportsSame topicMolecular spectroscopy and chiralityFrench-language works237,207