Multicenter Evaluation of the Feasibility of Clinical Implementation of SPECT Myocardial Blood Flow Measurement: Intersite Variability and Imaging Time

2023· article· en· W4387392011 on OpenAlexaffabout
R. Glenn Wells, Frank M. Bengel, Luca Camoni, Elisabetta Cerudelli, Sarah G. Cuddy‐Walsh, Johanna Diekmann, Lewis Han, Yoshito Kadoya, Naoto Kawaguchi, Yung Jih Felix Keng, Masao Miyagawa, Hagit Ratner, Terrence D. Ruddy

Bibliographic record

VenueCirculation Cardiovascular Imaging · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsCardiac PETCadmium zinc tellurideNuclear medicineBlood flowMyocardial perfusion imagingSingle-photon emission computed tomographyPositron emission tomographyMedicineCardiac imagingCoronary artery diseaseInterquartile rangeEmission computed tomographyCoronary flow reservePerfusionRadiologyPhysicsCardiologyInternal medicineOptics

Abstract

fetched live from OpenAlex

Background: Single-center studies have shown that single photon emission computed tomography myocardial blood flow (MBF) measurement is accurate compared with MBF measured with microspheres in a porcine model, positron emission tomography, and angiography. Clinical implementation requires consistency across multiple sites. The study goal is to determine the intersite processing repeatability of single photon emission computed tomography MBF and the additional camera time required. Methods: Five sites (Canada, Italy, Japan, Germany, and Singapore) each acquired 25 to 35 MBF studies at rest and with pharmacological stress using technetium-99m-tetrofosmin on a pinhole-collimated cadmium-zinc-telluride–based cardiac single photon emission computed tomography camera with standardized list-mode imaging and processing protocols. Patients had intermediate to high pretest probability of coronary artery disease. MBF was measured locally and at a core laboratory using commercially available software. The time a room was occupied for an MBF study was compared with that for a standard rest/stress myocardial perfusion study. Results: With motion correction, the overall correlation in MBF between core laboratory and local site was 0.93 (range, 0.87–0.97) at rest, 0.90 (range, 0.84–0.96) at stress, and 0.84 (range, 0.70–0.92) for myocardial flow reserve. The local-to-core difference in global MBF (bias -MBF ) was 5.4% (−3.8% to 14.8%; median [interquartile range]) at rest and 5.4% (−6.2% to 19.4%) at stress. Between the 5 sites, bias -MBF ranged from −1.6% to 11.0% at rest and from −1.9% to 16.3% at stress; the interquartile range in bias -MBF was between 9.3% (4.8%–14.0%) and 22.3% (−10.3% to 12.0%) at rest and between 17.0% (−11.3% to 5.6%) and 33.3% (−10.4% to 22.9%) at stress and was not significantly different between most sites. Both bias and interquartile range were like previously reported interobserver variability and less than the SD of the test-retest difference of 30%. The overall difference in myocardial flow reserve was 1.52% (−10.6% to 11.3%). There were no significant differences between with and without motion correction. The average additional acquisition time varied between sites from 44 to 79 minutes. Conclusions: The average bias -MBF and bias -MFR values were small with standard deviations substantially less than the test-retest variability. This demonstrates that MBF can be measured consistently across multiple sites and further supports that this technique can be reliably implemented. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03427749.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.059
Threshold uncertainty score0.542

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0140.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.071
GPT teacher head0.364
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueCirculation Cardiovascular ImagingSame topicCardiac Imaging and DiagnosticsFrench-language works237,207