Single-mode interband cascade laser based on V-coupled cavity with 210 nm wavelength tuning range near 3 µm
Bibliographic record
Abstract
Interband cascade lasers (ICLs) are efficient and compact mid-infrared (3-5 µm) light sources with many applications. By enhancing the coupling coefficient and using a type-I ICL wafer, single-mode ICLs were demonstrated based on V-coupled cavity with significantly extended tuning range and with a side mode suppression ratio (SMSR) exceeding 35 dB in continuous wave operation near 3 µm. A V-coupled cavity ICL exhibited a wavelength tuning up to 67 nm at a fixed temperature, and the total tuning range exceeds 210 nm when the heat sink temperature is adjusted from 80 to 180 K. The realization of single-mode in such a wide temperature range with a tuning range exceeding 210 nm verified the advantage of V-coupled cavity ICLs for effective detection of multiple gas species. This is very different from the conventional distributed feedback (DFB) laser where the single-mode operation is restricted to a narrow temperature range, in which the match between the gain peak and the DFB grating period determined wavelength is required. Another V-coupled cavity ICL is tuned over 120 nm from 2997.56 nm to 3117.50 nm with the heat-sink temperature varied from 210 K to 240 K, over 100 K higher than the previously reported maximum operating temperature for V-coupled cavity ICLs.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".