MétaCan
Menu
Back to cohort
Record W4387581621 · doi:10.1002/mp.16772

Audit of data from examination image headers collected for quality assurance in the ECOG‐ACRIN EA1151 tomosynthesis mammographic imaging screening trial (TMIST)

2023· article· en· W4387581621 on OpenAlexaff
Aili K. Maki, Gordon E. Mawdsley, James G. Mainprize, Etta D. Pisano, Sam Z. Shen, Olivier Alonzo‐Proulx, Martin J. Yaffe

Bibliographic record

VenueMedical Physics · 2023
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
FundersNational Cancer InstituteECOG-ACRIN Cancer Research GroupNational Institutes of HealthAmerican College of Radiology Imaging Network
KeywordsTomosynthesisQuality assuranceDICOMMammographyImage qualityMedical physicsBreast imagingImaging phantomDigital mammographyComputer scienceMedical imagingData qualityMedicineNuclear medicineRadiologyArtificial intelligenceBreast cancerCancer

Abstract

fetched live from OpenAlex

PURPOSE: A comprehensive, centrally-monitored physics quality control (QC) program was developed for the Tomosynthesis Imaging Screening Trial (TMIST), a randomized controlled trial of digital breast tomosynthesis (TM) versus digital mammography (DM) for cancer screening. As part of the program, in addition to a set of phantom-based tests, de-identified data on image acquisition and processing parameters were captured from the DICOM headers of all individual patient images in the trial. These data were analyzed to assess the potential usefulness of header data from digital mammograms and tomosynthesis images of patients for quality assurance in breast imaging. METHODS: Data were automatically extracted from the headers of all de-identified patient mammograms and tomosynthesis images in the TMIST study. Image acquisition parameters and estimated radiation doses were tracked for individual sites, systems and across system types. These parameters included (among others) kV, target/filter use, number of acquired views per examination, AEC mode, compression thickness and force and detector temperature. Consistency of manually entered study data parameters (subject ID, screening time-point) from TMIST was evaluated. Preliminary observations from the program are presented. RESULTS: We report on data from 812 651 images from 135 525 examinations acquired between October, 2017 and December, 2022. Data came from 6 system models from 3 manufacturers. There was greater variability both in the number of views used and in the estimated (proxy) doses received in DM exams compared to TM. Mean proxy doses per examination varied among manufacturers from 2.76-4.54 mGy for DM and 3-4.84 mGy for the tomosynthesis component in the TM arm with maximum examination proxy doses of 20 and 26 mGy for DM and TM respectively. Mean proxy doses per examination for the combination examination in TM (tomosynthesis plus digital mammography) varied from 6.6 to 7.6 mGy among manufacturers with a maximum of 44.5 mGy. CONCLUSIONS: Overall, modern digital mammography and tomosynthesis systems used in TMIST have operated very reliably. Doses vary considerably due to variation in the number of views per examination, thickness and fibro-glandularity of the breast, and choices in the use of synthesized versus actual 2D mammography in the TM examination. These data may also be useful in predicting equipment problems. Header information is valuable not only for automated QC, but also for cross-checking accuracy and consistency of data in a clinical study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.943
Threshold uncertainty score0.559

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.085
GPT teacher head0.357
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicDigital Radiography and Breast ImagingFrench-language works237,207