THE EFFECT OF ASCORBIC ACID ON GLUCOSE URINE ASSAY BY COPPER SULPHATE REDUCING SYSTEM AND HEXOKINASE METHOD.
Bibliographic record
Abstract
Background: The objective of the present study was to compare the results obtained by different methods used in glucose monitoring. Diabetic patients are known to use urine glucose strips or dipsticks tests or glucose pads for urine analysis. Blood glucose monitoring instruments such as different types of blood gluco-meters and digital blood glucose monitoring devices are also available in the local market for home glucose testing. Methodology: Some of those tests are officially used in the laboratories of different hospitals, where routine analysis is mainly done on advanced Chemical Analyzers. Results: Some discrepancies were observed in the results of glucose monitoring by different methods. A serious interference was recorded by ascorbic acid in reagent-strip reactions for assay of urinary glucose and hemoglobin. The test methods are known to be based on different chemical reactions including enzymatic and color reactions. Conclusion: Mostly, the urine concentration of ascorbic acid, uric acid, mercury, copper and iron were labeled to be the main cause of interference. In the present study 2991 urine samples having detectable ascorbic acid levels (?10 mg/dL) were tested by different methods and the results were compared with standard Dimension Chemical Analyzer (Dimension Dade Behring). Ascorbic acid in various concentrations was found to cause serious interference in glucose monitoring, however, hexokinase method was found more reliable.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.003 | 0.003 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.001 | 0.002 |
| Insufficient payload (model declined to judge) | 0.003 | 0.003 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".