MétaCan
Menu
Back to cohort
Record W4387901288 · doi:10.1093/eurpub/ckad160.1299

Long-term study using of short stems with ceramic-on-metal bearing in hip replacement

2023· article· en· W4387901288 on OpenAlexaboutno aff
Michela Saracco, Giandomenico Logroscino, Giulio Maccauro, Andrea Fidanza, Remo Goderecci, Francesco Falez, G Nasi

Bibliographic record

VenueEuropean Journal of Public Health · 2023
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsWOMACMedicineOsteoarthritisHarris Hip ScoreSurgeryArthroplastyBearing surfaceHip replacementDentistryMaterials science

Abstract

fetched live from OpenAlex

Abstract Background Osteoarthritis is a disease that affects about 300 million people in the world. Surgery is indicated in cases where all other treatments have failed, in economic terms expenses are between 1 and 2.5% of the GDP of the most industrialized countries in the world. Hip prosthetic replacement surgery is the gold standard for patients affected by symptomatic osteoarthritis. The ceramic-on-metal (C-M) hybrid hard-on-hard bearing was initially launched on the market with the purpose of reducing adhesive and corrosion wear, loss of metal debris and ions and risk of fracture and squeaking. However, this bearing was withdrawn from the market, in the apprehension of local and systemic toxicity. The aim of this study is to evaluate the reliability and safety of ceramic-on-metal bearing at long term follow-up. Methods From 2 cohorts of patients suffering of hip osteoarthritis who underwent total hip arthroplasty using ceramic-on-metal bearing with two different short stems, 19 of the GROUP A and 25 of the GROUP B were suitable for this study. All compared clinically using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), visual analogue scale (VAS), 12-item Short Form Health Survey (SF12P/M), and radiographically. The two groups were compared in terms of metal ions blood levels (chromium and cobalt), and finally all the implanted prostheses were compared with a healthy control group. Results All the implanted stems were well osseointegrated at a mean follow-up of 114 months. Radiographical and clinical scores performed well. Chromium and cobalt ion analysis revealed values below the safety threshold except for 3. No revision occurred. Conclusions Ceramic-on-metal bearing is safe and reliable at long term follow-up in association to short stems arthroplasty, if the implant is correctly positioned. Chromium and cobalt metal ions blood levels evaluation should be performed annually. Key messages • Metal ions evaluations is mandatory in patients with ceramic-on-metal bearing. • Ceramic-on-metal bearing is safe and reliable at long term follow-up, if the implant is correctly positioned.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.127
GPT teacher head0.352
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Public HealthSame topicOrthopaedic implants and arthroplastyFrench-language works237,207