Signal‐difference‐to‐noise comparison of temporal subtraction, kV‐switching dual‐energy and photon‐counting dual‐energy x‐ray angiography
Bibliographic record
Abstract
BACKGROUND: Dual-energy (DE) x-ray angiography with photon-counting detectors (PCDs) may enable single-exposure DE imaging of coronary vasculature. PURPOSE: To compare the iodine signal-difference-to-noise ratio (SDNR) of single-exposure DE angiography with digital subtraction angiography (DSA) and kV-switching DE angiography for matched patient x-ray exposure. METHODS: In a phantom study, we determined the technique parameters that maximized the iodine SDNR per root entrance air kerma for DSA, kV-switching DE angiography and single-exposure DE angiography. We measured SDNR from images of a phantom consisting of an iodine step-wedge immersed in a water tank of either 20 or 30 cm in thickness. We also imaged a phantom with simulated vessels embedded in background clutter and measured vessel SDNR. For this second phantom, we also applied anti-correlated noise reduction (ACNR) and calculated the resulting iodine SDNR. All images were acquired using a cadmium telluride PCD with two energy bins and analog charge summing for charge sharing suppression. The energy-discrimination capabilities were only used for the single-exposure DE approach. Optimized techniques were compared in terms of SDNR per root air kerma for two levels of x-ray scatter. RESULTS: For the same patient x-ray exposure, the SDNR of single-exposure DE imaging without ACNR was 75% to 85% of that of kV-switching DE imaging (also without ACNR) and DSA, the latter two of which had nearly equal SDNR. The single-exposure DE approach required ∼50% of the tube load of the kV-switching approach to achieve the same SDNR. For matched patient air kermas, the single exposure approach required only ∼25% of the tube load of the kV-switching approach. ACNR increased SDNR by 2.4 and 3.0 for kV-switching and single-exposure DE imaging, respectively. CONCLUSIONS: Photon-counting, single-exposure DE angiography can suppress soft tissues and provide iodine SDNR levels comparable to DSA and kV-switching DE angiography for matched patient radiation exposures. When ACNR is used to reduce DE image noise, the SDNR of single-exposure DE imaging and kV-switching DE imaging exceed that of DSA by more than a factor of two. Compared to kV-switching DE imaging, single-exposure DE imaging requires substantially lower tube loading to achieve the same SDNR.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.005 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".