MétaCan
Menu
Back to cohort
Record W4387965005 · doi:10.1002/mp.16811

Deep learning‐based ultrasound auto‐segmentation of the prostate with brachytherapy implanted needles

2023· article· en· W4387965005 on OpenAlexafffund
Prakash Hampole, Thomas H. Harding, Derek J. Gillies, Nathan Orlando, Chandima Edirisinghe, Lucas C. Mendez, David D’Souza, Vikram Velker, Rohann Correa, Joelle Helou, Shuwei Xing, Aaron Fenster, Douglas A. Hoover

Bibliographic record

VenueMedical Physics · 2023
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsRobarts Clinical TrialsLondon Health Sciences CentreWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchLondon Health Sciences Foundation
KeywordsProstate brachytherapyBrachytherapy3D ultrasoundSegmentationCoronal planeUltrasoundConvolutional neural networkMedicineArtificial intelligenceProstateSagittal planeNuclear medicineComputer scienceDeep learningRadiologyRadiation therapy

Abstract

fetched live from OpenAlex

BACKGROUND: Accurate segmentation of the clinical target volume (CTV) corresponding to the prostate with or without proximal seminal vesicles is required on transrectal ultrasound (TRUS) images during prostate brachytherapy procedures. Implanted needles cause artifacts that may make this task difficult and time-consuming. Thus, previous studies have focused on the simpler problem of segmentation in the absence of needles at the cost of reduced clinical utility. PURPOSE: To use a convolutional neural network (CNN) algorithm for segmentation of the prostatic CTV in TRUS images post-needle insertion obtained from prostate brachytherapy procedures to better meet the demands of the clinical procedure. METHODS: A dataset consisting of 144 3-dimensional (3D) TRUS images with implanted metal brachytherapy needles and associated manual CTV segmentations was used for training a 2-dimensional (2D) U-Net CNN using a Dice Similarity Coefficient (DSC) loss function. These were split by patient, with 119 used for training and 25 reserved for testing. The 3D TRUS training images were resliced at radial (around the axis normal to the coronal plane) and oblique angles through the center of the 3D image, as well as axial, coronal, and sagittal planes to obtain 3689 2D TRUS images and masks for training. The network generated boundary predictions on 300 2D TRUS images obtained from reslicing each of the 25 3D TRUS images used for testing into 12 radial slices (15° apart), which were then reconstructed into 3D surfaces. Performance metrics included DSC, recall, precision, unsigned and signed volume percentage differences (VPD/sVPD), mean surface distance (MSD), and Hausdorff distance (HD). In addition, we studied whether providing algorithm-predicted boundaries to the physicians and allowing modifications increased the agreement between physicians. This was performed by providing a subset of 3D TRUS images of five patients to five physicians who segmented the CTV using clinical software and repeated this at least 1 week apart. The five physicians were given the algorithm boundary predictions and allowed to modify them, and the resulting inter- and intra-physician variability was evaluated. RESULTS: Median DSC, recall, precision, VPD, sVPD, MSD, and HD of the 3D-reconstructed algorithm segmentations were 87.2 [84.1, 88.8]%, 89.0 [86.3, 92.4]%, 86.6 [78.5, 90.8]%, 10.3 [4.5, 18.4]%, 2.0 [-4.5, 18.4]%, 1.6 [1.2, 2.0] mm, and 6.0 [5.3, 8.0] mm, respectively. Segmentation time for a set of 12 2D radial images was 2.46 [2.44, 2.48] s. With and without U-Net starting points, the intra-physician median DSCs were 97.0 [96.3, 97.8]%, and 94.4 [92.5, 95.4]% (p < 0.0001), respectively, while the inter-physician median DSCs were 94.8 [93.3, 96.8]% and 90.2 [88.7, 92.1]%, respectively (p < 0.0001). The median segmentation time for physicians, with and without U-Net-generated CTV boundaries, were 257.5 [211.8, 300.0] s and 288.0 [232.0, 333.5] s, respectively (p = 0.1034). CONCLUSIONS: Our algorithm performed at a level similar to physicians in a fraction of the time. The use of algorithm-generated boundaries as a starting point and allowing modifications reduced physician variability, although it did not significantly reduce the time compared to manual segmentations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.017
Threshold uncertainty score0.034

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.276
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207