MétaCan
Menu
Back to cohort
Record W4388013898 · doi:10.5761/atcs.oa.23-00084

Total Arterial Revascularization: Evaluating the Length of the Radial Artery in a Composite Graft Configuration

2023· article· en· W4388013898 on OpenAlexaff
Jasmin H. Shahinian, Juan B. Grau, David Glineur

Bibliographic record

VenueAnnals of Thoracic and Cardiovascular Surgery · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac and Coronary Surgery Techniques
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsMedicineRadial arteryRevascularizationCardiologyInternal medicineArteryComposite numberComposite materialMaterials scienceMyocardial infarction

Abstract

fetched live from OpenAlex

PURPOSE: Reimplanting the radial artery in the left internal thoracic artery as a composite graft allows total arterial revascularization (TAR) without aortic manipulation. The limitation of this strategy is the length of the radial artery required to reach distal right coronary artery (RCA) branches. Our analysis focuses on the feasibility of this strategy. METHODS: A total of 169 patients underwent TAR using the radial artery in a composite grafting configuration. Length of the radial artery, number of sequential anastomoses, heart size, target location, length of the arm, patient height, body surface area, and flow in the composite graft were prospectively collected. RESULTS: The mean length of the radial artery was 18.02 cm. Patients with a mean length of the radial artery of 15.9 cm needed an extension of the radial artery with another conduit to reach the RCA distal branches. When T-configuration is used, the length of the radial artery should be 0.53 cm per sequential anastomosis to reach the RCA distal branches. CONCLUSIONS: Our study shows that an average length of 18.02 cm of radial artery is needed to reach targets on the RCA distal branches in composite grafting. In T-configuration, we need 0.53 cm more length per anastomosis to achieve TAR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.062
GPT teacher head0.340
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of Thoracic and Cardiovascular SurgerySame topicCardiac and Coronary Surgery TechniquesFrench-language works237,207