MétaCan
Menu
Back to cohort
Record W4388135844 · doi:10.59958/hsf.5739

Does False Lumen Thrombosis Lead to Better Outcomes in Patients with Aortic Dissection: A Meta-Analysis and Systematic Review

2023· review· en· W4388135844 on OpenAlexaboutno aff
Shiming Zhang, Wei Sun, Shidong Liu, Bing Song, Lili Xie, Ruisheng Liu

Bibliographic record

VenueThe Heart Surgery Forum · 2023
Typereview
Languageen
FieldMedicine
TopicAortic Disease and Treatment Approaches
Canadian institutionsnot available
FundersNatural Science Foundation of Gansu ProvinceLanzhou University
KeywordsMedicineMeta-analysisConfidence intervalCochrane LibraryRelative riskAortic dissectionInternal medicineSystematic reviewThrombosisSurgeryCardiologyMEDLINEAorta

Abstract

fetched live from OpenAlex

OBJECTIVES: For a long time, the association of the false lumen status and the outcomes of patients suffering from aortic dissection has been unclear, so this review article aims to study whether the unobstructed of the false lumen is related to the outcome of patients suffering from aortic dissection. METHODS: We performed this systematic review and meta-analysis according to the Preferred Reporting Items for Systematic Reviews and Meta Analyzes Protocols (PRISMA) statement 2009 and registered with PROSPERO (CRD42022381869). We searched PubMed, the Cochrane library, Web of Science and Embase to collect potential studies. The Newcastle-Ottawa Scale was used to assess the quality of the included studies. The main outcome is long-term survival. Data included in the study were summarized using the risk ratio or mean difference and 95% confidence interval. RESULTS: There were 16 trials, 2829 patients in total, with a mean age of 62.1 years. Compared with completely thrombosed false lumen, patent group has better long-term survival (risk ratio (RR), 0.88; 95% CI, 0.79 to 0.97; p = 0.01; I2 = 58%) and smaller yearly aortic growth rate (mean difference (MD), 1.03; 95% CI, 0.23 to 1.82; p = 0.01; I2 = 98%). In addition, patients with a patent false lumen had a lower risk of aortic event (RR, 0.81; 95% CI, 0.68 to 0.97; p = 0.02; I2 = 37%), but higher risk of aortic rupture (RR, 7.02; 95% CI, 2.55 to 19.3; p = 0.0002; I2 = 0) and hospital death (RR, 2.72; 95% CI, 1.45 to 5.08; p = 0.002; I2 = 0). CONCLUSION: Completely thrombosed of the false lumen is more beneficial to the long-term survival of patients with aortic dissection. And the risk of aortic rupture and hospital death in patients with patent false lumen is 7 times and 3 times that of patients with complete thrombosed false lumen. It is expected to provide individualized medical care for different types of patients according to different false lumen status to minimize death and related complications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.035
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.019
Threshold uncertainty score0.063

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.035
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0190.037
Bibliometrics0.0050.006
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0020.001
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.108
GPT teacher head0.351
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueThe Heart Surgery ForumSame topicAortic Disease and Treatment ApproachesFrench-language works237,207