MétaCan
Menu
Back to cohort
Record W4388460759 · doi:10.1016/j.jaip.2023.11.004

Performance Characteristics of Basophil Activation Tests for Diagnosing Penicillin Allergy: A Meta-Analysis

2023· review· en· W4388460759 on OpenAlexaff
Miriam Bennett, Alexander G. Mathioudakis, Jiakai Wu, Michael Chu, Chiara Tontini, Ιάσων Θωμάς, Angela Simpson

Bibliographic record

VenueThe Journal of Allergy and Clinical Immunology In Practice · 2023
Typereview
Languageen
FieldMedicine
TopicDrug-Induced Adverse Reactions
Canadian institutionsInstitute of Infection and Immunity
FundersNIHR Imperial Biomedical Research CentreManchester Biomedical Research CentreNational Institute for Health and Care Research
KeywordsMedicinePenicillinBasophil activationMeta-analysisAllergyPopulationConfidence intervalImmunologyAnaphylaxisInternal medicineIntensive care medicineBasophilPediatricsImmunoglobulin EAntibioticsAntibodyEnvironmental health

Abstract

fetched live from OpenAlex

BACKGROUND: Approximately 10% of the global population identify themselves as penicillin allergic, yet 90% are not truly allergic and could safely tolerate penicillin. There is no simple way to identify these people. Current in vitro diagnostics include specific immunoglobulin E (with a sensitivity of 19% and specificity of 97%) and a basophil activation test (BAT) with undefined sensitivity and specificity. OBJECTIVE: To define the sensitivity and specificity of BAT in the diagnosis of penicillin allergy METHODS: We searched PubMed and EMBASE from inception to April 2, 2023, for original studies evaluating the performance characteristics of BAT for penicillin allergy in adults. Study selection, data extraction, risk of bias, assessment with QUADAS-2 tool, certainty assessment with Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology were performed independently, in duplicate. Meta-analysis was performed using Reitsma methodology. RESULTS: Twenty-two studies fulfilled the inclusion criteria. Twelve used the same positive threshold giving a summary point sensitivity 51% (95% confidence interval [95% CI]46%-56%) and specificity 89% (95% CI 85%-93%). Significant risk of bias was identified owing to patient selection. GRADE certainty of evidence rated sensitivity very low due to imprecision and specificity as low. There was great heterogeneity in methods used. Use of 1,000 basophils per test did not improve performance above 500 basophils. CONCLUSIONS: BAT sensitivity is highly variable across studies and remains too low to be considered as a routine element of clinical practice. BAT specificity is not as good as specific immunoglobulin E in penicillin allergy diagnosis. Significant further work is required in this field before clinical application of BAT in routine practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.012
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.413
Threshold uncertainty score0.996

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.012
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0040.002
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.270
GPT teacher head0.472
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of Allergy and Clinical Immunology In PracticeSame topicDrug-Induced Adverse ReactionsFrench-language works237,207