MétaCan
Menu
Back to cohort
Record W4388557272 · doi:10.1093/milmed/usad034

Portable Single-Exposure Dual-Energy X-ray Detector for Improved Point-of-Care Diagnostic Imaging

2023· article· en· W4388557272 on OpenAlexaff
Karim S. Karim, Steven Tilley

Bibliographic record

VenueMilitary Medicine · 2023
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsDetective quantum efficiencyOptical transfer functionDigital radiographyDetectorImage qualityFlat panel detectorRadiographyNuclear medicineMedicineFluoroscopySensitivity (control systems)OpticsComputer visionArtificial intelligenceComputer scienceRadiologyPhysicsImage (mathematics)

Abstract

fetched live from OpenAlex

INTRODUCTION: Dual-energy subtraction (DES) imaging is well known to reduce anatomical noise and enable material classification. The current approaches to DES imaging have trade-offs, such as motion artifacts, low sensitivity because of losses in a mid-filter, and lack of portability. Recently, a portable triple-layer flat-panel detector (FPD) was proposed for use in single-shot DES imaging that can provide improved sensitivity and removal of motion artifacts in a point-of-care setting. The purpose of this study is to evaluate the feasibility of such a detector. Various image quality metrics and clinical images are provided. MATERIALS AND METHODS: An FDA-cleared single-exposure DES FPD consisting of three stacked sensors was used for all measurements. This detector generates three images per exposure: A digital radiography (DR) image, i.e., as would be produced with a conventional detector, and two DES images, bone and soft tissue. To evaluate DR image quality, detective quantum efficiency (DQE) and modulation transfer function were measured for multiple radiation quality beams. Digital radiography and DES images obtained from this FPD were evaluated in previously reported fixed and portable clinical studies. Digital radiography and DES images from case studies are presented for qualitative assessment. RESULTS: Modulation transfer function and DQE were measured across multiple radiation quality beams for the DR image. The DES images showed good tissue separation and uniformity with no visible motion or alignment artifacts. The DES images, when read in conjunction with the DR image, resulted in increased reader confidence and revealed abnormalities or details that were sometimes overlooked in the DR image. CONCLUSIONS: The proposed panel produces high-quality DR images as indicated by the DQE and modulation transfer function. The DES images have been shown to improve sensitivity in clinical applications and increase reader confidence. This detector can enable DES in portable or otherwise difficult applications, opening new doors for improved patient care.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.539
Threshold uncertainty score0.993

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.217
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueMilitary MedicineSame topicAdvanced X-ray and CT ImagingFrench-language works237,207