MétaCan
Menu
Back to cohort
Record W4388585211 · doi:10.5194/amt-2023-215

Radiative closure tests of collocated hyperspectral microwave and infrared radiometers

2023· preprint· en· W4388585211 on OpenAlexafffund
Lei Liu, Natalia Bliankinshtein, Yi Huang, John R. Gyakum, Philip Gabriel, Shiqi Xu, Mengistu Wolde

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicCalibration and Measurement Techniques
Canadian institutionsNational Research Council CanadaMcGill University
FundersFonds de recherche du Québec – Nature et technologiesCanadian Space AgencyCanada Foundation for InnovationEuropean Space AgencyUniversité du Québec à MontréalMcGill University
KeywordsZenithRadianceNadirRemote sensingRadiometerHyperspectral imagingMicrowave radiometerWater vaporEnvironmental scienceRadiative transferBrightness temperatureSkyOpticsMeteorologyBrightnessPhysicsGeographySatellite

Abstract

fetched live from OpenAlex

Abstract. Temperature and water vapor profiles are essential to climate change studies and weather forecasting. Hyperspectral instruments are of great value for retrieving temperature and water vapor profiles, enabling accurate monitoring of their changes. Successful retrievals of temperature and water vapor profiles require hyperspectral radiometer measurement accuracy. In this study, the radiometric accuracy of an airborne hyperspectral microwave radiometer, High Spectral Resolution Airborne Microwave Sounder (HiSRAMS), and a ground-based hyperspectral infrared radiometer, Atmospheric Emitted Radiance Interferometer (AERI), is simultaneously assessed by performing radiative closure tests under clear-sky conditions. As an airborne instrument, HiSRAMS has two radiometers measuring radiance in the oxygen band (49.6–58.3 GHz) and water vapor band (175.9–184.6 GHz) for zenith-pointing and nadir-pointing observations. AERI provides ground-based, zenith-pointing radiance measurements between 520 and 1800 cm-1. A systematic warm radiance bias is present in the temperature-sensitive channels in AERI observations in the window band. Upon removal of this bias, improved radiative closure was attained in the window band. The brightness temperature (BT) bias in nadir-pointing HiSRAMS observations is smaller than at the zenith. A novel but straightforward method is developed to diagnose the radiometric accuracy of the two instruments in comparison based on the relationship between radiometric bias and optical depth. Compared to AERI, HiSRAMS demonstrates similar radiometric accuracy for nadir-pointing measurements but exhibits relatively poor accuracy for zenith-pointing measurements, which requires further characterization. Future work on temperature and water vapor concentration retrievals using HiSRAMS and AERI is warranted.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.247
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes2
Has abstractyes

Explore more

Same topicCalibration and Measurement TechniquesFrench-language works237,207