MétaCan
Menu
Back to cohort
Record W4388691798 · doi:10.1002/rcm.9668

Development of <i>in situ</i> Li isotope analysis using laser ablation quadrupole inductively coupled plasma mass spectrometry

2023· article· en· W4388691798 on OpenAlexafffund
Xuefei Fan, Corliss Kin I Sio, Xu Chu, Hehe Jiang

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2023
Typearticle
Languageen
FieldAgricultural and Biological Sciences
TopicSilicon Effects in Agriculture
Canadian institutionsUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Toronto
KeywordsChemistryLaser ablationAnalytical Chemistry (journal)Mass spectrometryIsotopeInductively coupled plasma mass spectrometryMatrix (chemical analysis)Lithium (medication)Sample preparationLaserChromatographyOpticsNuclear physics

Abstract

fetched live from OpenAlex

Rationale Lithium isotope geochemistry is an important tool in the studies of Earth and planetary materials. In situ Li isotope analyses are typically performed using secondary ion mass spectrometry (SIMS) or laser ablation multicollector inductively coupled plasma mass spectrometry (LA‐MC‐ICPMS), but these instruments are not widely accessible. Here, the capability of laser ablation quadrupole ICPMS for conducting Li isotopic analyses is evaluated. Methods An array of MPI‐DING and USGS silicate glass reference materials was analyzed repeatedly over the course of 6 months. These materials range from komatiite to rhyolite in terms of silica content (45.5–75.6 wt%) with 9–45 ppm Li. Their Li isotope compositions have been previously characterized so that matrix effects could be tested with these reference materials. Analyses were conducted using an NWR193 laser ablation system coupled to an Agilent 7900 ICPMS system. Results Analytical precision is primarily limited by Li concentration in the samples. For samples with ~9 ppm Li, the internal precision is 6‰ (2 SD, 150 μm spot diameter), whereas that for a sample with ~45 ppm Li is 4‰ (2 SD, 120 μm spot diameter). The technique is somewhat sensitive to sample matrix: samples with SiO 2 content that deviates from the bracketing standard display fractionated δ 7 Li, necessitating correction using a session‐specific matrix correction curve. Conclusion Lithium isotope analysis by ns‐LA‐QICPMS is worthwhile for samples with high Li concentrations and when a matrix‐matched standard can be obtained. Although the precision of this method is not as high as those achievable with SIMS and LA‐MC‐ICPMS, it remains adequate for resolving large isotope fractionations found in natural and laboratory settings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.868
Threshold uncertainty score0.795

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.017
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.279
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicSilicon Effects in AgricultureFrench-language works237,207