Multiplane HiLo microscopy with speckle illumination and non-local means denoising
Bibliographic record
Abstract
Significance: HiLo microscopy synthesizes an optically sectioned image from two images, one obtained with uniform and another with patterned illumination, such as laser speckle. Speckle-based HiLo has the advantage of being robust to aberrations but is susceptible to residual speckle noise that is difficult to control. We present a computational method to reduce this residual noise without undermining resolution. In addition, we improve the versatility of HiLo microscopy by enabling simultaneous multiplane imaging (here nine planes). Aim: Our goal is to perform fast, high-contrast, multiplane imaging with a conventional camera-based fluorescence microscope. Approach: Multiplane HiLo imaging is achieved with the use of a single camera and z-splitter prism. Speckle noise reduction is based on the application of a non-local means (NLM) denoising method to perform ensemble averaging of speckle grains. Results: We demonstrate the capabilities of multiplane HiLo with NLM denoising both with synthesized data and by imaging cardiac and brain activity in zebrafish larvae at 40 Hz frame rates. Conclusions: Multiplane HiLo microscopy aided by NLM denoising provides a simple tool for fast optically sectioned volumetric imaging that can be of general utility for fluorescence imaging applications.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".