MétaCan
Menu
Back to cohort
Record W4388871638 · doi:10.1136/bmjdrc-2023-003545

Diagnostic accuracy of the 5.07 monofilament test for diabetes polyneuropathy: influence of age, sex, neuropathic pain and neuropathy severity

2023· article· en· W4388871638 on OpenAlexaboutno aff
Øystein Dunker, Martin Uglem, Marie Bu Kvaløy, Sissel Løseth, Ina Elen Hjelland, Sara Maria Allen, Maria Dehli Vigeland, Inge Petter Kleggetveit, Trond Sand, Kristian Bernhard Nilsen

Bibliographic record

VenueBMJ Open Diabetes Research & Care · 2023
Typearticle
Languageen
FieldMedicine
TopicPain Mechanisms and Treatments
Canadian institutionsnot available
FundersHaukeland UniversitetssjukehusNorges ForskningsrådMinistry of Education, India
KeywordsMedicineDiabetes mellitusPolyneuropathyInternal medicineLogistic regressionNeuropathic painOutpatient clinicDiseaseDiagnostic accuracyDiagnostic testDiabetic neuropathyPhysical therapyPediatricsAnesthesia

Abstract

fetched live from OpenAlex

INTRODUCTION: There is a need for simple and cheap diagnostic tools for diabetic polyneuropathy (DPN). We aimed to assess the diagnostic accuracy of the 5.07/10 g monofilament test in patients referred to polyneuropathy assessments, as well as to examine how disease severity, age, sex and neuropathic pain (NP) impact diagnostic accuracy. RESEARCH DESIGN AND METHODS: Five Norwegian university hospitals recruited patients with diabetes aged 18-70 referred to neurological outpatient clinics for polyneuropathy assessments. The 5.07/10 g Semmes-Weinstein monofilament examination (SWME) was validated against the Toronto consensus for diagnosing diabetic neuropathies; the results were stratified by age, sex and NP. Disease severity was graded by a combined nerve conduction study (NCS) Z-score, and logistic regression was applied to assess whether disease severity was a predictor of diagnostic accuracy. RESULTS: In total, 506 patients were included in the study. Global sensitivity was 0.60 (95% CI 0.55, 0.66), specificity 0.82 (95% CI 0.75, 0.87), positive and negative predictive values were 0.86 (95% CI 0.81, 0.90) and 0.52 (95% CI 0.46, 0.58), respectively, positive and negative likelihood ratios were 3.28 (95% CI 2.37, 4.53) and 0.49 (95% CI 0.42, 0.57), respectively. The SWME was less sensitive in females (0.43), had lower specificity in patients with NP (0.56), and performed worse in patients ≥50 years. NCS-based disease severity did not affect diagnostic accuracy (OR 1.15, 95% CI 0.95, 1.40). CONCLUSIONS: This multicenter study demonstrates poor diagnostic performance for the 5.07/10 g SWME in patients with diabetes referred to polyneuropathy assessments; it is particularly unsuited for female patients and those with NP. The diagnostic accuracy of the SWME was not influenced by NCS-based disease severity, demonstrating that it does not perform better in patients with later stages of DPN. We do not recommend the use of the 5.07/10 g monofilament in the evaluation of patients with diabetes referred to polyneuropathy assessments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.057
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.051
Threshold uncertainty score0.951

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.057
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.002
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.064
GPT teacher head0.395
Teacher spread0.331 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueBMJ Open Diabetes Research & CareSame topicPain Mechanisms and TreatmentsFrench-language works237,207