Electrical Impedance Tomography Hardware with Demodulation
Bibliographic record
Abstract
Electrical impedance tomography (EIT) is a promising imaging technology. It is portable, user-independent, and low cost (compared to other imaging technologies). There are two main approaches for EIT equipments: dynamic and absolute images. Absolute images are technologically more difficult and are limited by hardware. Phase information is required to create permittivity images. This is an ongoing research with the objective of evaluating the phase information. A new architecture with up to 64 electrodes is proposed. Each electrode has its own Howland current source and microcontroller. The proposed hardware consists of three main modules: the electrode hardware (with Howland current source and microcontroller); the demodulator algorithm; and, the electrode synchronizer. Some results are presented with the electrode hardware that demonstrate data acquisition with two electrodes. Tests with the demodulator algorithm were also presented. Simulated tests with the designed electrode synchronizer were performed, and the implementation remains, and it is considered a future work.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.003 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.002 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.013 | 0.004 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".