MétaCan
Menu
Back to cohort
Record W4389122781 · doi:10.22374/jclrs.v7i1.54

Wear Experience with a Daily Disposable Soft Contact Lens for Astigmatism in Current Wearers of a Reusable Soft Toric Contact Lens

2023· article· en· W4389122781 on OpenAlexvenueno aff
Jennifer Swingle Fogt, Nidhi Satiani, Kimberly Patton

Bibliographic record

VenueJournal of Contact lens Research and Science · 2023
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsnot available
FundersNational Center for Advancing Translational Sciences
KeywordsContact lensMedicineInterquartile rangeOptometryPatient satisfactionLens (geology)Visual analogue scaleOphthalmologyPhysical therapySurgeryEngineering

Abstract

fetched live from OpenAlex

Objective: The purpose of this study was to evaluate the wear experience of satisfied wearers of a particular reusable toric soft contact lens when refit into a water surface technology daily disposable toric soft contact lens. Methods: 30 participants completed the study over three visits. At the first visit, subjects were refit into with their habitual reusable toric soft contact lens (comfilcon A) to maximize fit and vision. Subjects returned after one week and were then refit into the study daily disposable soft contact lenses (verofilcon A) and completed surveys of their initial impressions of comfort, vision, and satisfaction. Participants wore the study lenses for two weeks, and then returned for their final visit to complete a vision and ocular health check. At the final visit, subjects also completed surveys to rate their overall and end-of-day comfort, quality of vision, stability of vision, and dryness using a visual analog scale (VAS). Participants also answered questions about their wear experience with the lenses. Overall median and interquartile range (IQR) of all data and surveys was calculated. Results: Initial impressions of the study lenses revealed a median (IQR) score of 85 (28) for vision, 91 (25) for comfort, and 87 (21) for satisfaction. Overall VAS scores after two weeks of wear found median scores of 93 (16) for quality of vision, 88 (28) for stability of vision, and 91 (20) for comfort. End-of-day median scores were 82(27) for quality of vision, 90 (35) for stability of vision, and 80 (38) for comfort. Overall dryness scores were 20(45) and end-of-day dryness was 39 (46). Median(IQR) binocular logMAR visual acuity with the study lenses was -0.16(0.1). Median rotation of the lenses was 0(4.3) degrees. Conclusion: Participants wearing the daily disposable study lenses for astigmatism gave high scores in vision and comfort both at initial fitting and after two weeks of lens wear. Results showed that satisfied wearers of comfilcon A reusable toric soft contact lenses can be successfully refit with verofilcon A daily disposable contact lenses.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.519
Threshold uncertainty score0.905

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0000.001
Scholarly communication0.0000.002
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.379
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Contact lens Research and ScienceSame topicOcular Surface and Contact LensFrench-language works237,207