Utilisation of the Scepter Mini dual-lumen balloon – An illustrative series
Bibliographic record
Abstract
BackgroundDual-lumen balloon microcatheters can aid in the safety and efficacy of endovascular embolisation of cerebrospinal vascular malformations. The Scepter Mini dual-lumen balloon is a novel device with a smaller profile than previous balloon microcatheters, opening up new indications not only in the treatment of cerebrospinal malformations but in various other neurovascular therapeutic and diagnostic scenarios.MethodsFollowing institutional ethics review board approval, a retrospective review of our prospectively maintained database of cases employing the Scepter Mini dual-lumen microballoon catheter was conducted. Five cases in particular were highlighted, demonstrating utilisation of this device, which may be of interest to the Neurointerventionalist. Patient demographics, procedure details, complications and clinical outcome data were reviewed.ResultsFive cases employing the Scepter Mini dual-lumen microballoon catheter are presented; trans-arterial embolisation of cerebral AVM, pre-operative tumour embolisation, diagnostic angiography, trans-venous embolisation of cerebral AVM and trans-arterial embolisation of DAVF. No intraprocedural complications were recorded, one patient had a delayed haemorrhage.ConclusionPotential utilisation of the Scepter Mini lies not only in the trans-arterial embolisation of cerebrospinal vascular malformations, but in a range of other diagnostic and therapeutic indications as demonstrated.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".