Experimental study of a heat recovery ventilator preheated by a Building Integrated Photovoltaic system in a cold climate
Bibliographic record
Abstract
Abstract The use of heat recovery ventilators (HRVs) in cold climate housing is becoming increasingly common, to provide outside air to the occupied space while recovering heat from the exhausted air. However, frosting of the heat exchanger core impedes HRV operation in cold climate conditions. Strategies for defrosting the core include recirculating the exhaust airstream while stopping the supply of the outside air during the defrost cycle. Preheating the air using heating coils is also used, but its application is limited by the increased energy use of the preheater. This study aims to investigate the impact of a building integrated photovoltaic/thermal (BIPV/T) system on the HRV thermal performance by using it to preheat the outside air. In this experimental study, measurements of a heat recovery ventilator preheated by the BIPV/T system are carried out in a test cell of the Future Buildings Laboratory (FBL) at Concordia University in Montreal, Canada. The results are compared to a HRV without BIPV/T preheating. The relative humidity, temperature and airflow rate of the fresh air and exhaust airstreams are monitored at the inlet and outlet of the HRV. The experiments are conducted during two weeks from January 26 th , 2023 to February 08 th , 2023. The change of the sensible heat recovery effectiveness ∈ sens of the HRV, outside air outlet temperature T 2 from the HRV and outside air flow rate, ṁ 1 and exhaust air flow rate ṁ 4 are determined. The primary experimental results indicate that preheating the outside air by the BIPV/T system before entering the HRV can help to increase the outside air outlet temperature T 2 by up to 2.7°C at an outdoor temperature of -25 °C, and the sensible heat recovery effectiveness ∈ sens , outside air flow rate, ṁ 1 (23L/s) and exhaust air flow rate ṁ 4 (43L/s) of the HRV are kept constant at the same level with preheating by BIPV/T on the HRV at -5 °C to -25 °C of outdoor temperature.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".